Search
العربية
English
Español
Français
العربية
Русский
Português
हिन्दी
বাংলা
Deutsch
日本語
Bahasa Indonesia
Italiano
RFQ
Home
Market
Solutions
Knowledge
Download the app
MENU
Home
Market
Solutions
Knowledge
العربية
English
Español
Français
العربية
Русский
Português
हिन्दी
বাংলা
Deutsch
日本語
Bahasa Indonesia
Italiano
Home
Knowledge
Circuit
Topics
Power Systems
Power system
Machines
circuit diagram
Measurement
Basic Electrical
Basic
Industrial circuit
Basic knowledge
Transmission
Electric Power Knowledge
Control
Motor
Transformer
Electric Motors
Protection
household circuit
Generation
Control Circuit
Switchgear
Solution principle for high voltage vacuum interrupter
Enhancing Dielectric Strength in Vacuum Gaps for High-Voltage InsulationThere are primarily two methods to increase the dielectric strength of a vacuum gap to meet the insulation requirements at high voltage (HV):Increase the Contact Distance in a Two-Contact Configuration: In a vacuum, breakdown is predominantly a surface effect, heavily influenced by the condition of the contact surfaces. Unlike in SF6 gas, where breakdown is primarily a volume effect that scales linearly with the gap length,
Edwiin
12/13/2024
What are the benefits and drawbacks of ring main electrical systems?
Advantages and Disadvantages of a Ring Main Electrical SystemA ring main electrical system is a common topology for distribution networks, especially in medium-voltage and low-voltage power distribution systems. It connects multiple loads or distribution points in a closed loop to distribute electricity. Below are the advantages and disadvantages of a ring main electrical system:I. AdvantagesHigh Reliability Redundant Power Supply: A ring system has two paths for power supply. Even if one sectio
Encyclopedia
12/12/2024
Voltage Escalation in Shunt Reactor Switching in Circuit Breakers
Shunt-Reactor Switching: A Common Practice in Inductive-Load SwitchingShunt-reactor switching is one of the most common practices in inductive-load switching. Shunt reactors are installed to compensate for overhead-line capacitance and are switched in or out based on the momentary line load. Since a shunt reactor can be treated as a lumped circuit element with stray capacitance, the equivalent load circuit can be simplified to a straightforward LC (inductor-capacitor) circuit.Voltage Oscillation
Edwiin
12/12/2024
Transient Recovery Voltage(TRV) in Interruption of Small Inductive Currents by Circuit Breakers
Analyzing Transient Phenomena in Linear Systems Using the Principle of SuperpositionIn analyzing transient phenomena caused by switching operations in linear systems, the principle of superposition is a powerful tool. By combining the steady-state solution that existed before the open-circuit operation with the transient responses induced by short-circuit voltage sources and open-circuit current sources, and considering the current injected through the switch contacts, a comprehensive descriptio
Edwiin
12/11/2024
AC Circuit Breakers Routine Tests according to IEC 62271-100
To ensure the superior quality and performance of each AC circuit breaker in terms of materials, design, and assembly, manufacturers perform routine tests on every unit produced. These tests are essential for verifying the reliability and safety of the circuit breakers, confirming their ability to function correctly under specified conditions.For multi-phase circuit breakers consisting of multiple breaker units (such as V-type or T-type configurations), routine testing is conducted on the fully
Edwiin
12/10/2024
High voltage Incoming and outgoing feeders configuration in switch yards
The incoming and outgoing feeders of switchgear cabinets are typically equipped with circuit breakers, isolating switches, and earthing switches to ensure the safe operation of the power system. In high-voltage switch stations, each feeder is also fitted with current transformers (CTs) and potential transformers (PTs) to connect protection and measurement devices. CTs are positioned on the busbar side of the PTs to allow protection devices to detect short circuits in the PTs. For feeders without
Edwiin
12/09/2024
Out of phase current switching in High Voltage Circuit Breakers
When two parts of an electrical network with the same operating voltage are coupled, a phase displacement switching phenomenon occurs if their equivalent sources have different phase angles, with some or all phases being 180° out of phase. During the switching operation, the circuit breaker encounters source voltages with differing phase angles, leading to the presence of phase-displaced currents in the connection. These currents must be reliably interrupted by the circuit breakers on both s
Edwiin
12/07/2024
Pipeline instrumentation circuit diagram template
Pipeline instrumentation circuit diagram template
Master Electrician
12/06/2024
Photovoltaic system structure
Photovoltaic system structure
Master Electrician
12/06/2024
Graphic symbols commonly used in photovoltaic energy systems
Graphic symbols commonly used in photovoltaic energy systems
Master Electrician
12/06/2024
1
2
···
10
11
12
13
14
···
69
70
Source professional electrical partners, experts, and explore smart grid & energy solutions.
Inquiry
Send Now
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!