• Single-phase pad-mounted transformers with protective functions
Single-phase pad-mounted transformers with protective functions
discuss personally
Model
ZGS
Basic info
Brand Vziman
Model NO. Single-phase pad-mounted transformers with protective functions
Rated frequency 50/60Hz
Primary voltage 2400-19920 V
Secondary voltage 120-600 V
Capacity range 10-167 kVA
Series ZSG
Product Detail

Descripton:

The Completely Self-Protection (CSP) single-phase pad-mounted transformer is designed with the core objective of achieving excellent performance. It integrates a directly connected primary surge arrester, a MagneX arc extinguishing chamber, or a secondary circuit breaker with a built-in primary voltage fuse. There is no need to install additional independent protective equipment, which significantly reduces the installation cost.
The power range of this series of transformers covers 10 - 75 kVA. When equipped with a MagneX arc extinguishing chamber, the power range can be expanded to 10 - 167 kVA, and its performance fully meets or even exceeds relevant standards such as ANSI and NEMA.
In addition, the CSP transformer supports two types of filling media. It can be filled with standard electrical-grade mineral insulating oil or FR3 liquid with excellent fire resistance, flexibly adapting to different usage scenarios.

Features:

  • Equipped with an internal overcurrent device and a surge arrester, it can achieve efficient overvoltage protection without the need for external independent protective components. For secondary faults and overloads, it can provide dual reliable protection through a secondary circuit breaker with weak links or an optional MagneX arc extinguishing chamber.
  • It supports the free choice of two filling media: FR3 fireproof insulating oil, which greatly enhances the fire safety level; or standard electrical-grade mineral oil to meet regular usage requirements. The product performance comprehensively surpasses industry standards and performs excellently in terms of ANSI specifications, NEMA standards, and DOE energy efficiency requirements.
  • The core and coils are deeply optimized in design. Aiming to achieve high reliability and a low failure rate, it offers two materials, grain-oriented steel and amorphous steel, to adapt to different performance needs. Both the high-voltage and low-voltage bushing terminals are tinned, making them compatible with aluminum and copper conductors to ensure stable and reliable electrical connections.
  • The exterior design takes into account both functionality and aesthetics, offering two style options: the MaxiShrub style equipped with an ANSI Type-1 front panel, or the Shrubline style with an ANSI Type-2 front panel. Both adopt a low-profile design and can better blend into the surrounding environment.

Technical Parameters:

Specifications:

  • Meet or exceeds ANSI, NEMA and DOE2016 standards
  • IEEE standards C57.12.00, C57.12.38, C57.12.28, C57.12.35, C57.12.90, C57. 91 and C57.154
  • NEMA standards, NEMA TR 1 (R2000)
  • Department of Energy Efficiency Standard, 10 CFR Part 431
  • Tank coating exceeds IEEE Std C57.12.28-2005 and C57.12.29-2005 standards (stainless steel units only)
  • Full compliance with IEEE Std C57.12.28-2005 standard enclosure integrity requirements
  • FR3 fluid or electrical grade mineral oil
  • Cores and coils designed for high reliability and low field failure rates: Available in grain-oriented electrical or amorphous steel
  • The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following:
  • 55 °C, 55/65 °C, 65 °C
  • The applicable AWR rating shall be specified on the inquiry
  • The transformer shall be designed in accordance with this specification and shall have one of the following kVA ratings:
  • 10, 15, 25, 37.5, 50, 75, 100, 167
  • The applicable kVA rating shall be specified on the inquiry
  • Quality System ISO 9001 certified
Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What does the recloser testing process in Nigeria involve?
What does the recloser testing process in Nigeria involve?
The testing of reclosers in Nigeria is a rigorous, multi-stage process designed to ensure compliance with local regulations, adaptability to harsh environmental conditions, and reliable operation across diverse grid landscapes. Below is an in-depth exploration of the key testing phases and their technical implications:1. Regulatory Compliance: SONCAP Certification and NERC StandardsReclosers entering Nigeria’s market must first navigate mandatory regulatory hurdles. SONCAP certification in
Oliver Watts
06/04/2025
What are the key considerations for recloser selection in Nigeria?
What are the key considerations for recloser selection in Nigeria?
When selecting reclosers for power distribution networks in Nigeria, several critical factors must be addressed to ensure reliable, efficient, and compliant operation. Here's a breakdown of key considerations:1. Voltage Compatibility: 11kV StandardsNigeria’s distribution grid widely operates at the 11kV voltage level. Reclosers must be rated for 11kV to seamlessly integrate into the network. This ensures they can handle the system’s voltage demands, whether in urban, rural, or indust
James
06/04/2025
How does the merger device achieve distribution network feeder automation?
How does the merger device achieve distribution network feeder automation?
AC High - Voltage Automatic Recloser (Recloser for Short in This Article)The AC high - voltage automatic recloser (referred to as the recloser for short in this article) is a high - voltage switchgear with self - control (it has the functions of fault current detection, operation sequence control and execution by itself, without the need for additional relay protection and operation devices) and protection functions. It can automatically detect the current and voltage passing through the main ci
Echo
06/04/2025
Short Circuit Ratio of a Synchronous Machine
Short Circuit Ratio of a Synchronous Machine
The Short Circuit Ratio (SCR) of a Synchronous MachineThe Short Circuit Ratio (SCR) of a synchronous machine is defined as the ratio of the field current needed to generate rated voltage under open-circuit conditions to the field current required to sustain rated armature current during a short-circuit condition. For a three-phase synchronous machine, the SCR can be derived from its Open-Circuit Characteristic (O.C.C) at rated speed and Short-Circuit Characteristic (S.C.C), as illustrated in the
Edwiin
06/04/2025
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
1. IntroductionIn Vietnam's coastal regions, 20kV reclosers play a critical role in maintaining power supply reliability amid harsh environmental conditions. These devices, compliant with IEC 62271-111 and Vietnam's national standard TCVN, are frequently exposed to salt fog, high humidity, and typhoons, necessitating robust fault management strategies. This article explores typical malfunctions of IP67-rated reclosers in Vietnam and proposes integrated solutions to enhance grid resilience.2. Env
Felix Spark
06/03/2025
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
1. IntroductionIn the modern power grid infrastructure, high - voltage reclosers play a pivotal role in enhancing the reliability and efficiency of power supply. This is particularly crucial in regions like Indonesia, which has a vast and complex power distribution network spanning numerous islands, and Vietnam, with its developing coastal power systems. The 20kV voltage level, falling within the medium - high - voltage range, is widely adopted in urban grids, industrial power supply, and certai
Dyson
06/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放