Search
Italiano
English
Español
Français
العربية
Русский
Português
हिन्दी
বাংলা
Deutsch
日本語
Bahasa Indonesia
Italiano
RFQ
Home
Market
Solutions
Knowledge
Download the app
MENU
Home
Market
Solutions
Knowledge
Italiano
English
Español
Français
العربية
Русский
Português
हिन्दी
বাংলা
Deutsch
日本語
Bahasa Indonesia
Italiano
Home
Knowledge
Power Systems
Topics
Power Systems
Power system
Machines
circuit diagram
Measurement
Basic Electrical
Basic
Industrial circuit
Basic knowledge
Transmission
Electric Power Knowledge
Control
Motor
Transformer
Electric Motors
Protection
household circuit
Generation
Control Circuit
Switchgear
SF6 gas detection thermal camera high voltage substation
One method for detecting SF6 gas leakage in a substation is to use a reliable infrared camera with SF6 gas detection capabilities. This enables the identification of potential leaks during routine maintenance rounds. These new - generation infrared cameras integrate a high - performance thermal imager with a reliable pistol - grip form factor and SF6 gas detection functionality.These devices offer several advantages over other methods, as detailed below:They allow maintenance to be scheduled at
Edwiin
03/28/2025
Lightning impulse voltage withstand test for circuit breakers
Lightning impulse voltage (LIWL) tests and switching impulse voltage tests are carried out to assess the dielectric stress resulting from transient over - voltages induced by lightning strikes and switching operations respectively. An impulse voltage generator produces a steep - front voltage waveform, which is then applied to the test object. A measurement system, consisting of a voltage divider and a digital recorder, is used to measure and analyze the test voltages and their waveforms.The fig
Edwiin
03/27/2025
Primary & Backup Protection
Primary ProtectionPrimary protection, also known as main protection, serves as the first - line of defense. It is designed to rapidly and selectively clear faults within the boundaries of the specific circuit section or element it safeguards. Each section of an electrical installation is equipped with primary protection. This protection mechanism is engineered to respond promptly to abnormal conditions, ensuring that the affected area is isolated as quickly as possible to minimize damage and dis
Edwiin
03/27/2025
Three phase high power synthetic current injection test methods for circuit breakers
This test just apply to 3 pole operation circuit breakers.As Fig these circuits use a three-phase current source and, generally, two voltage sources. one voltage source provides the TRV for the first pole-to-clear and the other gives the recovery voltage for the second- and third poles-to-clear, in the case where these poles clear simultaneously as in non-effectively earthed systems.This system have following components: A three phase current source (G) Voltage source 1 with current injection pa
Encyclopedia
03/26/2025
What is Fluxmeter?
What is Fluxmeter?DefinitionA flux meter is an instrument designed to measure the magnetic flux of a permanent magnet. It represents an advanced iteration of the ballistic galvanometer, boasting certain advantages. Specifically, the flux meter features low controlling torque and significant electromagnetic damping.Construction of Flux MeterThe construction of the flux meter is depicted in the figure below. The flux meter incorporates a coil that is freely suspended using a spring and a single si
Encyclopedia
03/25/2025
What is Creeping in Energy Meter?
What is Creeping in Energy Meter?DefinitionCreeping in an energy meter is a phenomenon where the aluminium disc rotates continuously when only voltage is applied to the pressure coil and no current flows through the current coil. In essence, it is an error causing the energy meter to consume a minute amount of energy even when no load is connected to the meter.Impact and Causes of CreepingCreeping can increase the disc's rotation speed even under light - load conditions, leading to inflated mete
Edwiin
03/25/2025
What is Synchro?
What is Synchro?DefinitionA Synchro is a type of transducer that converts the angular position of a shaft into an electrical signal. It functions as both an error detector and a rotary position sensor. Errors in the system often occur due to shaft misalignment. The two main components of a synchro are the transmitter and the control transformer.Synchro System TypesThere are two types of synchro systems:Control Type Synchro Torque Transmission Type Synchro Torque Transmission Type SynchrosThis ki
Encyclopedia
03/24/2025
What is Three Phase Energy Meter?
What is Three Phase Energy Meter?DefinitionA three - phase energy meter is an instrument designed to measure the power of a three - phase electrical supply. It is constructed by connecting two single - phase meters via a shaft. The total energy consumption is determined by summing the readings of both elements.Working Principle of Three - Phase Energy MeterThe torques generated by the two elements are mechanically combined. The total rotation of the shaft is directly proportional to the energy c
Edwiin
03/24/2025
What is Earth Tester?
Definition:An earth tester is an instrument designed for measuring the resistance of the earth. In a power system, all equipment is connected to the earth via an earth electrode. The earth plays a vital role in safeguarding both the equipment and personnel from fault currents. The resistance of the earth is extremely low, allowing the fault current passing through the earth electrode to be safely dissipated into the ground, thus protecting the power system from damage.Earth electrodes are also c
Encyclopedia
03/22/2025
Ammeter Shunt
Definition:An ammeter shunt is a device that offers a low - resistance path for the flow of current. It is connected in parallel with the ammeter. In certain ammeters, the shunt is built - into the instrument, while in others, it is externally attached to the circuit.Reason for Connecting the Shunt in Parallel with the AmmeterAmmeters are designed to measure low currents. When it comes to measuring heavy currents, a shunt is connected in parallel with the ammeter. Due to its low - resistance pat
Encyclopedia
03/22/2025
1
2
···
10
11
12
13
14
···
104
105
Source professional electrical partners, experts, and explore smart grid & energy solutions.
Inquiry
Send Now
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!