• RWV-300 High Performance AC DRIVE
RWV-300 High Performance AC DRIVE
discuss personally
Model
RWV300 G6-030
RWV300 G2-5D5
RWV300 G1-2D2
RWV300 G3-1D5
RWV300 G5-022
Basic info
Brand RW Energy
Model NO. RWV-300 High Performance AC DRIVE
Output current 35A
Power capacity 40kVA
Input current 40A
Adapt motor 30kW
Series RWV
Product Detail

Description :

A Variable Frequency Drive (VFD) is a power control device widely used in the field of industrial automation. It integrates functions such as motor control, energy-saving regulation, communication, and monitoring, enabling precise speed control and operational status management of AC motors.The VFD adopts a modular design concept, offering high flexibility and programmability, which significantly reduces maintenance workload and spare parts requirements while meeting diverse application needs. As an ideal alternative to traditional motor control methods, the VFD provides notable advantages in improving energy efficiency, optimizing control accuracy, and extending equipment lifespan.

Main function introduction:

  • Chinese and English LCD display, easy to install and debug;

  • The Japanese wide and large structure, the product margin is large,

  • Can be used in hot weather occasions;

  • With speed tracking function, can be a good application of fan secondary start;

  • Can do 220V, 380V, or 220/380 and other voltages;

  • With short circuit, grounding and other protection;

  • Can add master/slave control card, communication expansion card, PG card;

  • Asynchronous motor, synchronous motor optional;

Product model description

image.png

Technology parameters:

image.png

image.png

image.png

image.png

image.png

image.png

image.png

Wiring Schematic Diagram :

企业微信截图_17402046418189.png

What is a variable frequency drive?

A variable frequency drive is an electronic device that can convert alternating current (AC) of a fixed frequency into AC with adjustable frequency and voltage, thereby controlling the speed and torque of an electric motor. It mainly consists of a rectifier that converts AC into direct current (DC). After voltage stabilization in the DC link, an inverter then converts the DC back into AC with the required frequency and voltage. It is widely used in industries, heating, ventilation, and air - conditioning (HVAC) systems, the automotive sector, etc., to achieve motor speed regulation, energy conservation, and precise operation control.


Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Public.
RWV Series High Performance AC DRIVE
Manual English
Consulting
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放