• Arc-proof Air-insulated Switchgear for Primary Distribution  12kV 630...2000A 25kA
Arc-proof Air-insulated Switchgear for Primary Distribution 12kV 630...2000A 25kA
discuss personally
Model
LeanGear ZS9-12
Basic info
Brand ABB
Model NO. Arc-proof Air-insulated Switchgear for Primary Distribution 12kV 630...2000A 25kA
Rated voltage 12kV
Rated frequency 50/60Hz
Series LeanGear ZS9
Product Detail

Description:

LeanGear ZS9 is an arc-proof air-insulated switchgear designed to meet space requirements and ratings of low electrical distribution grids.

It offers optimal safety and reliability standards, consistent with the ABB’s UniGear range of switchgear. With a proven robustness and flexibility,  the LeanGear ZS9 is tested for tropical conditions.

Main benefits:

  • Safety: Increased safety level assured by integrated ducting system against effects of internal arc.
  • Security: Comprehensive interlocks provide optimum protection for both personnel and equipment.
  • Space: Maximum functionality in a compact design with reduced footprint and height.
  • Service: Ease of service and operation by personnel as switchgear and cable termination height are ergonomically designed.
  • Speed: Minimal service downtime attributable to modular circuit breaker design and built-in features that eliminate use of special handling tools.
  •  Strength: Robust panel structure that is proven against external mechanical impacts.

Main features:

  • Type-tested to IEC standard by STL lab.
  • Internal arc classification IAC AFLR 25kA 1s.
  • Classified as LSC2B, PM.
  • Up to 1250A, proven for severe climatic conditions compliant to IEC 62271-304 Class 2.
  • CB racking with closed door.
  • Cable termination height of 700 mm.
  •  IP4X degree of protection.
  • Extensible on both sides.
  • Integrate with ABB Relion® series relay for protection and control.
  •  For Higher Altitude contact ABB.

VInd/L circuit breaker:

  • Floor-rolling circuit breaker.
  • Suitable for E2, M2, and C2 endurance class application.
  •  Integral spring charging handle.
  •  Built-in mechanical anti-pumping device.

Single line diagram of typical units:

Typical feeder unit:

 A: Circuit breaker compartment
 B: Busbar compartment
 C: Cable compartment
 D: Low voltage compartment
 E: Integral panel gas duct

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
LeanGear ZS9 Arc-proof Air-insulated Switchgear for Primary Distribution
Manual English
PDF
FAQ
Q: What support and services does ABB provide for installation, commissioning, and after-sales maintenance?
A: ABB provides comprehensive support services including installation, commissioning, and after-sales maintenance. Our team of experts ensures smooth deployment and ongoing support to maximize the performance and longevity of our switchgear products.
Q: What smart solutions are available for ABB’s AIS portfolio?
A: ABB’s switchgear smart solutions are designed to help our customers make data-driven decisions. Our customers can benefit from a wide range monitoring, diagnostic, automation and control features for their ABB’s air-insulated medium voltage switchgear. Contact our sales team to learn more about ABB’s smart solutions for each of our switchgear.
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放