• Arc-proof Air-insulated Switchgear for Primary Distribution  12kV 630...2000A 25kA
Arc-proof Air-insulated Switchgear for Primary Distribution 12kV 630...2000A 25kA
discuss personally
Model
LeanGear ZS9-12
Basic info
Brand ABB
Model NO. Arc-proof Air-insulated Switchgear for Primary Distribution 12kV 630...2000A 25kA
Rated voltage 12kV
Rated frequency 50/60Hz
Series LeanGear ZS9
Product Detail

Description:

LeanGear ZS9 is an arc-proof air-insulated switchgear designed to meet space requirements and ratings of low electrical distribution grids.

It offers optimal safety and reliability standards, consistent with the ABB’s UniGear range of switchgear. With a proven robustness and flexibility,  the LeanGear ZS9 is tested for tropical conditions.

Main benefits:

  • Safety: Increased safety level assured by integrated ducting system against effects of internal arc.
  • Security: Comprehensive interlocks provide optimum protection for both personnel and equipment.
  • Space: Maximum functionality in a compact design with reduced footprint and height.
  • Service: Ease of service and operation by personnel as switchgear and cable termination height are ergonomically designed.
  • Speed: Minimal service downtime attributable to modular circuit breaker design and built-in features that eliminate use of special handling tools.
  •  Strength: Robust panel structure that is proven against external mechanical impacts.

Main features:

  • Type-tested to IEC standard by STL lab.
  • Internal arc classification IAC AFLR 25kA 1s.
  • Classified as LSC2B, PM.
  • Up to 1250A, proven for severe climatic conditions compliant to IEC 62271-304 Class 2.
  • CB racking with closed door.
  • Cable termination height of 700 mm.
  •  IP4X degree of protection.
  • Extensible on both sides.
  • Integrate with ABB Relion® series relay for protection and control.
  •  For Higher Altitude contact ABB.

VInd/L circuit breaker:

  • Floor-rolling circuit breaker.
  • Suitable for E2, M2, and C2 endurance class application.
  •  Integral spring charging handle.
  •  Built-in mechanical anti-pumping device.

Single line diagram of typical units:

Typical feeder unit:

 A: Circuit breaker compartment
 B: Busbar compartment
 C: Cable compartment
 D: Low voltage compartment
 E: Integral panel gas duct

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
LeanGear ZS9 Arc-proof Air-insulated Switchgear for Primary Distribution
Manual English
PDF
FAQ
Q: What support and services does ABB provide for installation, commissioning, and after-sales maintenance?
A: ABB provides comprehensive support services including installation, commissioning, and after-sales maintenance. Our team of experts ensures smooth deployment and ongoing support to maximize the performance and longevity of our switchgear products.
Q: What smart solutions are available for ABB’s AIS portfolio?
A: ABB’s switchgear smart solutions are designed to help our customers make data-driven decisions. Our customers can benefit from a wide range monitoring, diagnostic, automation and control features for their ABB’s air-insulated medium voltage switchgear. Contact our sales team to learn more about ABB’s smart solutions for each of our switchgear.
Related Products
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放