• AC load bank 3KW-5MW
AC load bank 3KW-5MW
discuss personally
Model
DRLB-200
DRLB-150
DRLB-120
DRLB-100
DRLB-20
DRLB-10
DRLB-5
DRLB-3
Basic info
Brand Wone
Model NO. AC load bank 3KW-5MW
Power 200KW
Series DRLB
Product Detail

Description

  • It is used for the detection and maintenance of AC power supply equipment, performance testing of various switches and contactors, loading,
    burn-in, simulated load test, etc.

  • Power Range: 1kW-5MW (others on request).

  • Current Range: 0.1A-15000A.

  • Working Voltage Range: single phase, 3 phases, or custom requests.

  • Multiple safety protection functions : short circuit, over-current, over voltage, over-load, over temperature, fan fault, audible and visual alarm
     device, etc.

  • It can be designed with RS232 and RS485 to connect with PC for remotecontrol.

  • Forced air cooling and water cooled are available.

  • Production Time :3-4 weeks
    Widely used in test equipment, such as generator load, charging pile test,inverter power supply, data center test, server room load test, UPS, etc.


Parameter

Dimensions (mm)
Power L±5 W±5 H±5 h±5
3KW 580 380
250
70
5KW 680 380 250 70
6KW 680 450 250 70
8KW 450
500 700
70
10KW 500 500 800 100
15KW 500 550 800 100
20KW 600
600 800 100
25KW 600 650 800 100
30KW 600 650 1000
100
40KW 680
680
1100 100
50KW 680 680 1200 100
60KW 850
850
1200 100
80KW 850 850 1300
150
100KW 850
850 1400 150
120KW 900 850 1400 150
150KW 900 850 1500
150
200KW 1000
850 1500 150
300KW 1400 1200 1650 150
400KW 1500 1200 1800
150
500KW 1500
1400 1800 150
600KW 1500 1500 1800 150
800KW 1800 1500 1900
150
1000KW 2000
1500 1900 150
1200KW 2000 1600
1900 150
1500KW 2200 1600 1900 150
2000KW 2400 1800
2000
150



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放