• 40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)
40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)
discuss personally
Model
ZHW58A-72.5/4000-40
ZHW58A-72.5/3150-31.5
ZHW58A-40.5/4000-40
ZHW58A-40.5/2500-31.5
Basic info
Brand Wone
Model NO. 40.5(72.5)kV Hybrid GIS
Rated voltage 72.5kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series ZHW58A-40.5(72.5)
Product Detail

Product introduction:

ZHW58A series was originally designed to meet the needs of power construction and hybrid product development, and its main application scenario is to meet the needs of 35-500KV substation expansion; At present, ZHW58A-40.5/72.5 products have reached the leading level at home and abroad in terms of technical advancement and quality reliability.

Main characteristic:

  •  Current transformers, isolation, grounding switch combination, compact, lightweight design, which can realize the whole transportation, save area, relative AlS station save covers an area of 70%, suitable for power plant and substation construction, expansion or reconstruction project and railway electrification construction, especially suitable for old substation upgrading, reduce the construction difficulty and investment scale.

  • CT is arranged on two sides of the circuit breaker (different from the structure of mainstream manufacturer’s' similar products, complying with the requirement "blind area of main protection shall be avoided in the configuration of protective current transformer and the allocation of secondary winding" as specified in the Technical specifications of Relay Protection and Safety Automatic Device, improving the reliability of power supply.

  • The product also adopts straight-through CT, completely solving problems such as excess moisture and low insulation margin and promoting the insulation resistance and reliability of the product.

  •  The product is configured with a grounding switch on equipment side and line side in a built-in way, with reliable earthing that prevents safety hazards in maintenance.

  • The circuit breaker adopts light-spring operating mechanism and aluminum frame of integral casting. It’s closing-opening springs adopt spiral dual-pressure spring, with a compact and indefatigable structure, realizing a mechanical life of 10000compressions.

  •  Aviation plugs are used to connect CB, DES & ES mechanism cases and control cabinet, facilitating field installation and commissioning.

  •  The structure of three-position disconnecting/grounding switch is stable and reliable.

  •  The inlet and outlet lines are connected to the equipment through bushings. Composite insulation bushings and porcelain bushings can be selected., Compared with GlS equipment, the enclosed bushings are omitted, and theSF6 gas consumption is less (less than 50% of GiS consumption), which is green and economical.

Main technical parameters:

image.png

Order Notice:

  • Application working condition (incoming/outgoing line, main transformer or PT interval);

  • Rated electrical parameters (voltage, current, breaking current and so on);

  • Conditions of use environment (ambient temperature, altitude and class of environmental pollution);

  • Control voltage of operating mechanism and motor voltage;

  • Quantity. current ratio, grade combination and secondary load of current transformer;

  • Name and quantity of spare products, spare parts & special tools and equipment (to be ordered separately).

What are the structural characteristics of hybrid high-voltage gas-insulated switchgear? 

Hybrid Gas Insulation System:

  • Typically, a mixture of SF₆ and other gases (such as N₂, CF₄, etc.) is used as the insulating medium. This design aims to combine the properties of different gases. For example, SF₆ has excellent insulating and arc-quenching properties but poses environmental concerns due to its greenhouse effect. By mixing it with other gases, the amount of SF₆ can be reduced while maintaining good insulation performance. The insulation system consists of sealed gas compartments that enclose the high-voltage conductive parts, preventing contact with the external environment and ensuring reliable electrical insulation.

Compact Design Layout:

  • To fully utilize the insulating properties of the hybrid gas, the internal structure of the equipment is designed to be compact. Various components of the switchgear, such as circuit breakers, disconnect switches, earthing switches, and busbars, are carefully arranged to minimize the overall size of the equipment. For example, compact circuit breaker designs and optimized busbar layouts enable efficient electrical connections and functional integration within a limited space.

Reliable Sealing Structure:

  • To ensure good insulation performance, the hybrid gas must be maintained at specific pressure and purity levels. Therefore, the equipment features highly reliable sealing structures. High-quality sealing materials (such as rubber O-rings, metal gaskets, etc.) and sealing techniques are used to ensure the airtightness of the gas compartments and prevent gas leakage. Additionally, the sealing structure must withstand temperature changes, mechanical vibrations, and other factors, maintaining stable sealing performance over the long term.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.