• 252kV HV gas-insulated metal-enclosed switchgear(GIS)
252kV HV gas-insulated metal-enclosed switchgear(GIS)
$1200.00
Model
ZF29-252
Basic info
Brand Wone
Model NO. 252kV HV gas-insulated metal-enclosed switchgear(GIS)
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50(Hz)
Series ZF29-252
Product Detail

Description:

ZF29-252 gas-insulated metal-enclosed switchgear (referred to as GIS) is used for three-phase AC 50HZ, 220KV power system. The product adopts a common-phase three-station isolated grounding switch structure and modular design, which can meet various wiring methods.

Industry applications:

It is mainly used in power plants, substations, and large industrial and mining enterprises. Divide and combine no-load, load and fault currents, conversion loads, isolation lines, grounding protection and measurement of power transmission and transformation systems.

Features:

  • The circuit breaker adopts horizontal arrangement, the arc extinguishing chamber adopts a single-break double-acting structure, and the self-energy arc extinguishing principle is equipped with a low-power spring operating mechanism, which effectively reduces mechanical stress, has high mechanical operation reliability, and has a mechanical life of 10,000 times.

  •   Adopt three-station isolation grounding switch structure, mechanical interlocking between isolation and grounding, effectively avoid misoperation, high reliability, and mechanical life of 10,000 times.

  •   Three-station isolation grounding switch and main bus adopt three-phase co-box structure. The sealing surface and bonding surface of SF6 gas are reduced, which greatly reduces the air leakage rate; The three-station isolated grounding switch has no complex external connecting rods and connectors, simple structure and excellent corrosion resistance.

  • The rated SF6 gas pressure is low, except for the circuit breaker, the other gas chambers are rated at 0.4MPa, which greatly reduces the use of SF6 gas and reduces the greenhouse effect.

Technical parameters:

image.png

image.png

Dimension:

企业微信截图_17160150106667.png


Product show:

SloFyeCBRhu6SBvSmY_jNw.jpg_500xaf.jpg


Why choose us:

  • We have a professional service team.

  • We have good after-sales.

  • We can guarantee the quality of our products.

What is the insulation principle of gas-insulated switches?

Insulation Principle:

  • In an electric field, the electrons in SF₆ gas molecules are slightly displaced from the nuclei. However, due to the stability of the SF₆ molecular structure, it is difficult for electrons to escape and form free electrons, resulting in high insulation resistance. In GIS (Gas-Insulated Switchgear) equipment, the insulation is achieved by precisely controlling the pressure, purity, and electric field distribution of the SF₆ gas. This ensures a uniform and stable insulating electric field between the high-voltage conductive parts and the grounded enclosure, as well as between different phase conductors.

  • Under normal operating voltage, the few free electrons in the gas gain energy from the electric field, but this energy is not sufficient to cause collision ionization of the gas molecules. This ensures the maintenance of the insulating properties.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry
Download