• 15kV Indoor MV Digital Vacuum Circuit Breaker
15kV Indoor MV Digital Vacuum Circuit Breaker
discuss personally
Model
PacT-15-2000
Basic info
Brand Schneider
Model NO. 15kV Indoor MV Digital Vacuum Circuit Breaker
Rated voltage 15kV
Rated normal current 2000A
Rated frequency 50/60Hz
Series EvoPacT
Product Detail

Description:

The next generation, natively digital CB for panel builders and users of MV switchgear in Primary Distribution applications. Includes scalable connectivity, with integrated sensors, IoT and a HMI that enables remote digital operation from outside of the arc flash zone. Anticipate and detect abnormal conditions with 24/7 condition monitoring and best-in class interlocking for a safety first approach. Durable and designed for life, all compliant with latest industry cybersecurity standards.

EvoPacT medium voltage (MV) breakers are integrated with embedded sensors for proactive health monitoring, inside of SureSeT Metal-Clad switchgear, helping data and controls become visible locally or remotely for increased efficiency and reduced risk.

EvoPacT breakers are designed to be smaller and stronger, built for 26" wide sections for space savings, and increased mechanical testing for reliability. EvoPacT can be easily scaled and upgraded to accommodate your growing needs.

Product specifications:

  • Tested to 3X the industry standard, with 30,000 mechanical operations and a newly designed vacuum interrupter (tested to 30,000 operations at rated current)

  • IEEE/ANSI, UL/UR rated, and compliant with industry cybersecurity standards

  • EvoPacT digital circuit breakers work with your connected solutions. By collecting and analyzing performance data, you can optimize operations throughout your facility

  • EvoPacT’s comprehensive monitoring and control platform is accessible through a connected device and is compliant with industry cybersecurity standards

  • Designed to be modular, flexible, and easily upgraded, EvoPacT digital circuit breakers come in a scalable range of connectivity tiers, to fit your growing needs

  • Sensors, monitoring, and control features are easily scaled. Upgrading is a smooth process, available when your facility is ready

  • Green Premium certified, part of our commitment to deliver sustainable performance for our customers

 Technical Characteristics:

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High voltage/Low voltage
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
9 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr