• Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV
Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV
discuss personally
Model
VD4G-25
Basic info
Brand ABB
Model NO. VD4G generator circuit breaker Small footprint, full protection for generator applications
Rated voltage 15kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series VD4G
Product Detail

Description:

ABB offers its new vacuumgenerator circuit breakers at 15 kV,4000 A, 63 kA in accordance to thenew Dual Logo IEEE/IEC 62271-37-013 standard to satisfy yourbusiness needs in power generation applications.

Features:

Protect your assets

  • Use a solution completely inaccordance with the latest global standards - IEC as well as IEEE

  • Count on a generator circuit breakersuitable for all highly demanding conditions, including out-of-phase condition and island mode

  • Be safe thanks to a completely testedsolution for DC-component up to130%, so no need to add any time delay in the protection

Maximize your output

  • Experience the easy installation/integration of VD4G, thanks to itsinterfaces and dimensions equivalentto the standard version VD4

  • Accelerate your projects with theoutstanding technical support grantedby our Field Application Engineeringm team

Optimize your investment

  • Choose ratings that fit your needs from 25/16 kA @ 15 kV to 63/50 kA @ 15 kV

  • Take advantage of using the samecompact switchgear setup like inpower distribution systems

Technical characteristics:

Standards IEEE/IEC 62271-37- 013

 

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
VD4G generator circuit breaker Small footprint, full protection for generator applications
Manual English
PDF
FAQ
Q: What is a generator circuit breaker?
A: A generator circuit breaker (GCB) is a specialized switchgear device used in power generation systems to safely connect or disconnect a generator from the electrical grid or load. It is designed to interrupt high fault currents, protect the generator from overloads, short circuits, and other electrical faults, and ensure reliable operation during normal and abnormal conditions.
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放