• Self-powered single-phase recloser  for up to 27 kV
  • Self-powered single-phase recloser  for up to 27 kV
Self-powered single-phase recloser for up to 27 kV
discuss personally
Model
Eagle-27-200
Eagle-15-200
Basic info
Brand ABB
Model NO. Self-powered single-phase recloser for up to 27 kV
Rated voltage 27kV
Rated normal current 200A
Rated frequency 50/60Hz
Series Eagle
Product Detail

Product Introduction

Product Range:Up to 27kV, 200A, 8kA

ABB’s Eagle is a single phase self-powered vacuum interrupting recloser. It can be mounted directly to the pole as a new installation or a replacement to oil filled single-phase reclosers. It can be installed separately on single phase laterals or in a group of three for a three-phase lateral circuit.
Eagle recloser drastically improves the reliability indices for utilities simply by eliminating the sustained interruptions experienced by the customers due to fuse-blowing schemes and momentary interruptions due to fuse-saving schemes. By reducing the number of truck rolls, the utility can save on operational costs and at the same time avoid revenue losses due to outages.
Eagle provides highest interrupting rating among its class with higher BIL (basic insulation level) and continuous current rating providing application from major three-phase feeder laterals to the end-of-line single phase laterals.

Technical parameters

The following technical parameters fully present the product's electrical parameter configurations, mechanical performance parameters, and dimensional details to facilitate precise system integration and application planning.

Key features

Key features highlight the product’s innovative design, high-performance capabilities, and operational advantages, ensuring optimal suitability for diverse industrial and power system requirements.

  • Can function as a recloser, breaker, or a sectionalizer
  • Main operating handle for mechanical opening, closing and resetting without relying on battery backup
  • Mounting design that allows manual swing down open for a visual disconnect
  • Conventional open/close indicator cup semaphore and a LED beacon for lockout indication
  • Adaptable non-reclose and hot line tag modes
  • Wide selection of fuse, recloser and user programmable protection curves
  • Platform / device independent web-based user interface
  • Full event, security, loading and fault recording capability with GPS time stamps
  • 128-bit encryption with WPA2 level security for Wi-Fi connection
  • Cold load pickup and 2nd harmonic inrush blocking for each curve

Key benefits

Key benefits underscore the product’s reliability, efficiency, and cost-effectiveness, delivering tangible value for power distribution and industrial applications.

  • Can be applied on circuits up to 27kV, 200A – avoiding need to stock multiple part numbers
  • High fault current rating (8 kA) allows installation across the feeder
  • Self-powered design eliminating the need for an external power source
  • “No arcing” operations to keep personnel safety intact
  • Battery-free operations provide a truly maintenance-free life cycle
  • Ability to restore power after an extended outage without the need for batteries
  • One-to-one replacement for hydraulic reclosers by using identical mounting and protection curves
  • Hassle-free web-based interface and secure Wi-Fi communication
Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High voltage/Low voltage
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
1. Statistics on Common Faults of Medium-Voltage Switchgear in the Early Operation StageAs project participants, we found during the early operation of a new metro line: 21 sets of power supply equipment were put into use, with a total of 266 accident phenomena in the first year. Among them, 77 faults occurred in medium-voltage switchgear, accounting for 28.9%—significantly higher than faults in other equipment. Statistical analysis shows that major fault types include: protection device s
Felix Spark
06/11/2025
Practice of Intelligent Switchgear Transformation in the 6kV Working Section of a Power Plant
Practice of Intelligent Switchgear Transformation in the 6kV Working Section of a Power Plant
Due to the long service life and severe aging of the equipment, the switches in the 6kV working section of Unit 6 of a certain power plant have potential safety hazards such as deformed locating pins, abnormal closing positions of the earthing switches, and malfunctions of the protection devices. These hazards have threatened the stable operation of the unit, making the transformation extremely urgent. Meanwhile, considering the recent cases of electric shock casualties involving medium-voltage
Echo
06/11/2025
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放