• Rectifier Transformer (distribution transformer)
Rectifier Transformer (distribution transformer)
discuss personally
Model
SR11-4000/10
Basic info
Brand Vziman
Model NO. Rectifier Transformer (distribution transformer)
Rated capacity 4000KVA
Voltage grade 10KV
Series Rectifier Transformer
Product Detail

Product overview:

  •  A rectifier transformer is a transformer that converts the power supply of the grid into the power supply required by the rectifier equipment.

  •  Rectifier transformers (intermediate frequency furnace transformers) are widely used in.

  • Chemical industry (most used industry) electrolysis of non-ferrous metal compounds to produce aluminum, magnesium, copper and other metals; Electrolytic salt to make chlor-alkali. Electrolysis of water to produce hydrogen and oxygen.

  • Dc power supply for traction is used for DC power grid of mine or urban electric locomotive.

  • Dc power supply for transmission.

  •  Mainly used to supply power to DC motors in electric transmission, such as armature and excitation of rolling mill.

  • Other applications, including DC power supply for electroplating or electroprocessing, DC power supply for excitation, DC power supply for charging and electrostatic dust removal, etc.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Products are mainly exported to Iran, Kazakhstan, Uzbekistan and other countries and regions.

  •  Implementation standard: IEC 60076 series.

Leading technology:

  •  Large capacity, low loss, low noise (< 65dB) more energy saving.

  •  Excellent performance index, actual measurement is better than GB and IEC standards.

  • The product has strong over-load capacity and over-voltage capacity, and can run safely for a long time under rated load.

  • Strong impact resistance and short circuit resistance.

  • With microcomputer protection device (measurement, control, protection, communication, etc.).

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Use heat dissipation tubing (double row and three row tubing adopt insert mode) to achieve good heat dissipation effect.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  •  Normal delivery period is 30 days.

  • Worldwide fast delivery.

What is a Rectifier Transformer?

Functional Aspects:

  • A rectifier transformer is a special type of transformer, mainly used to convert alternating current (AC) voltage into a voltage suitable for the input of a rectifier. The function of a rectifier is to convert alternating current into direct current (DC), and the rectifier transformer provides the appropriate alternating current input voltage for the rectifier to ensure that the rectifier can perform the rectification operation effectively.

  • For example, in the industrial electroplating process, a stable direct current power supply is required for electroplating operations. The rectifier transformer first converts the alternating current from the power grid (such as 380V AC) into an alternating current voltage suitable for the electroplating rectifier (such as an alternating current voltage of several tens of volts), and then the rectifier converts this alternating current voltage into a direct current voltage for electroplating.

Structural Characteristics:

  • Its structure is similar to that of an ordinary transformer, also having an iron core and windings. However, the winding design of the rectifier transformer may be more complex because the direct current output characteristics after rectification need to be taken into account.

  • For example, in order to reduce the harmonic components in the direct current after rectification, the windings of the rectifier transformer may adopt special connection methods, such as extended delta connection or zigzag connection. These connection methods help to improve the electrical performance of the transformer, making the output alternating current voltage more suitable for rectification, thus obtaining a better-quality direct current output.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放