• RCW-E15M 15kV MV outdoor vacuum recloser
  • RCW-E15M 15kV MV outdoor vacuum recloser
  • RCW-E15M 15kV MV outdoor vacuum recloser
RCW-E15M 15kV MV outdoor vacuum recloser
$5000.00
RCW-E15M/1250-25C
RCW-E15M/1250-25
RCW-E15M/800-20C
RCW-E15M/800-20
RCW-E15M/630-16C
RCW-E15M/630-16
RCW-E15M/400-12.5C
RCW-E15M/400-12.5
RCW-E15M/400-12.5
RCW-F15M/1250-25C
RCW-F15M/1250-25
RCW-F15M/800-20C
RCW-F15M/800-20
RCW-F15M/400-12.5C
RCW-F15M/400-12.5
RCW-F15M/630-16
RCW-F15M/630-16C
Basic info
Brand ROCKWILL
Model NO. RCW-E15M 15kV MV outdoor vacuum recloser
Rated voltage 15kV
Rated normal current 1250A
Rated short circuit breaking current 25kA
Power frequency withstand voltage 28kV/min
Rated lightning impulse voltage 95kV
manual closing Yes
Mechanical lock No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overheaddistribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’srecloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters

Rated maximum voltage

15kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

16kA

Rated peak value withstand current

40kA

Rated 1min power frequencywithstand voltageThree-phase Epoxy resin pole

28kV

Rated lightning impulse voltage(Three-phase Epoxy resin pole)

95kV

Operation sequence

C-0.5-CO-2-CO-5-COMagnetic actuator

Mechanical life

n:30000Magnetic actuator

Power supply and operating voltage

110/220V( Customized)

Ratio of current transformer

400/1A( Customized)

Number of voltage sensorsThree-phase Epoxy resin pole

≤3

Opening time

≤30msMagnetic actuator

Closing time

≤40msMagnetic actuator

Minimum creepage distance

31level4mm/kv

Minimum distance between phases

360mm

Potential transformer

110/220V( Customized)

Cable length

6,8,12m( Customized)

Cable clampThree-phase Epoxy resin pole

2-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection& logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(*)

Over-voltage protection./Under voltage protection

Programable protection relay curves total 10 nos ANSI/IEC curves

Cold load pickup protection TCC +Hot line tag

Earth protection EF/SEF +Zone Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support(*)

Modbus communication protocol is optional(*)

IEC 60870-5-101 communication protocol support

IEC 60870-5-104 communication protocol support.(*)

The recloser can communicate through GPRS(Or GSM) modem with English or Specified language (*)

With optional functions for use

Rated currents, System phase current.

Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequency, 

power(kWh), reactive power(kV arh), power factor

With optional reclosing interval for user pre-program

Reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note: (*) mean should customized by manufacturer if needed


External dimensions:

企业微信截图_17103058136732.png


Environmental requirement:

Maximum temperature:

+40℃

Minimum temperature:

-30℃

Monthly average humidity

                          95%

Humidity:

                          90%

Above sea level:

2500m or higher

Ambient air not apparently polluted by corrosive and flammable gas, vapor


Product show:

不代手合正方形硅橡胶永磁.png

带手合正方形 硅橡胶永磁带手合.png

What is the vacuum arc extinguishing fault of outdoor vacuum recloser and its solution?

Vacuum Arc Quenching Chamber Faults:

  • Decreased Vacuum Level: This is a common issue with vacuum arc quenching chambers. The vacuum arc quenching chamber relies on a high-vacuum environment to extinguish arcs. If the vacuum level decreases, its insulation performance and arc-quenching ability will significantly deteriorate. The causes of decreased vacuum levels can include poor sealing, such as aging or damaged sealing materials, or tiny leaks present during the manufacturing process. When the vacuum level drops to a certain extent, incomplete arc extinction may occur during current interruption, leading to arc reignition and subsequent line faults.

  • Contact Wear: During frequent opening and closing operations, the contacts of the vacuum arc quenching chamber can wear down due to arc erosion. Contact wear increases contact resistance, which can lead to severe heating of the contacts when normal current passes through, affecting the normal operation of the equipment. Additionally, during fault current interruption, the contacts may not withstand the high current, resulting in contact welding or failure to interrupt the current.

Solutions for Vacuum Arc Quenching Chamber Faults:

Vacuum Level Decrease:

  • Detect Vacuum Level: Use specialized vacuum level detection instruments, such as vacuum level testers, to regularly check the vacuum level of the vacuum arc quenching chamber. Once the vacuum level is found to be below the specified value, the vacuum arc quenching chamber should be replaced promptly.

  • Replace Seals: If you suspect that poor sealing is causing the decrease in vacuum level, inspect and replace the seals. When replacing seals, ensure that you use high-quality, compatible sealing materials and follow the correct installation procedures to prevent further leakage.

Contact Wear:

  • Regular Inspection: Regularly inspect the wear condition of the contacts through observation windows or by disassembling the device. Based on the degree of wear, if the wear exceeds the specified limit, the contacts should be replaced promptly.

  • Optimize Operating Parameters: Analyze the causes of contact wear, such as whether it is due to frequent operations or excessive operating current. If the issue is frequent operation, consider optimizing the recloser's reclosing strategy to reduce unnecessary opening and closing operations. If the issue is excessive operating current, check the line load conditions, adjust the protection settings, and avoid subjecting the contacts to excessive current impacts.


Other recommendations
New Knowledges
Free Download Now
Wone is dedicated to serving the personnel in the global power industry.
Join WONE, not only can you discover power equipment and power knowledge, but also can find like-minded friends!
Message
Email
Inquiry
Inquiry