• 15kV/1250A MV outdoor vacuum Auto Circuit recloser
15kV/1250A MV outdoor vacuum Auto Circuit recloser
$5000.00
Model
RCW-E15M/1250-25C
RCW-E15M/1250-25
RCW-E15M/800-20C
RCW-E15M/800-20
RCW-E15M/630-16C
RCW-E15M/630-16
RCW-E15M/400-12.5C
RCW-E15M/400-12.5
RCW-E15M/400-12.5
RCW-F15M/1250-25C
RCW-F15M/1250-25
RCW-F15M/800-20C
RCW-F15M/800-20
RCW-F15M/400-12.5C
RCW-F15M/400-12.5
RCW-F15M/630-16
RCW-F15M/630-16C
Basic info
Brand ROCKWILL
Model NO. 15kV/1250A MV outdoor vacuum Auto Circuit recloser
Rated voltage 15kV
Rated normal current 630A
Rated short circuit breaking current 16kV
Power frequency withstand voltage 36kV/min
Rated lightning impulse voltage 110kV
manual closing Yes
Mechanical lock
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overheaddistribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’srecloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters

image.png

image.png


Environmental requirement:

image.png

Product show:

不代手合正方形硅橡胶永磁.png

带手合正方形 硅橡胶永磁带手合.png

What is the vacuum arc extinguishing fault of outdoor vacuum recloser and its solution?

Vacuum Arc Quenching Chamber Faults:

  • Decreased Vacuum Level: This is a common issue with vacuum arc quenching chambers. The vacuum arc quenching chamber relies on a high-vacuum environment to extinguish arcs. If the vacuum level decreases, its insulation performance and arc-quenching ability will significantly deteriorate. The causes of decreased vacuum levels can include poor sealing, such as aging or damaged sealing materials, or tiny leaks present during the manufacturing process. When the vacuum level drops to a certain extent, incomplete arc extinction may occur during current interruption, leading to arc reignition and subsequent line faults.

  • Contact Wear: During frequent opening and closing operations, the contacts of the vacuum arc quenching chamber can wear down due to arc erosion. Contact wear increases contact resistance, which can lead to severe heating of the contacts when normal current passes through, affecting the normal operation of the equipment. Additionally, during fault current interruption, the contacts may not withstand the high current, resulting in contact welding or failure to interrupt the current.

Solutions for Vacuum Arc Quenching Chamber Faults:

Vacuum Level Decrease:

  • Detect Vacuum Level: Use specialized vacuum level detection instruments, such as vacuum level testers, to regularly check the vacuum level of the vacuum arc quenching chamber. Once the vacuum level is found to be below the specified value, the vacuum arc quenching chamber should be replaced promptly.

  • Replace Seals: If you suspect that poor sealing is causing the decrease in vacuum level, inspect and replace the seals. When replacing seals, ensure that you use high-quality, compatible sealing materials and follow the correct installation procedures to prevent further leakage.

Contact Wear:

  • Regular Inspection: Regularly inspect the wear condition of the contacts through observation windows or by disassembling the device. Based on the degree of wear, if the wear exceeds the specified limit, the contacts should be replaced promptly.

  • Optimize Operating Parameters: Analyze the causes of contact wear, such as whether it is due to frequent operations or excessive operating current. If the issue is frequent operation, consider optimizing the recloser's reclosing strategy to reduce unnecessary opening and closing operations. If the issue is excessive operating current, check the line load conditions, adjust the protection settings, and avoid subjecting the contacts to excessive current impacts.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Design of Remote Closing Device for Indoor Handcart High-Voltage Vacuum Circuit Breaker
Design of Remote Closing Device for Indoor Handcart High-Voltage Vacuum Circuit Breaker
The cabling and undergrounding of urban power grid lines have become an irreversible trend in distribution network construction. High-voltage switchgear, as the core equipment of the distribution system, has become the main object of daily operation and maintenance for maintenance personnel. During the equipment iteration process, the comprehensive replacement and commissioning of new equipment have a long cycle, and a type of old hand-cranked high-voltage switchgear is still in service.Due to l
Dyson
06/07/2025
Design and Development of WVT-12 Vacuum Circuit Breaker
Design and Development of WVT-12 Vacuum Circuit Breaker
I. Market and Technical ResearchSince 2003, I have been engaged in the key project of localizing WVT-12 vacuum circuit breaker technology for Anhui Longbo Company. At that time, in the 12kV voltage class, vacuum circuit breakers had occupied more than 98% of the total circuit breakers. With the advancement of power grid construction and the growth of industrial and residential electricity demand, the domestic and international markets have shown a continuous upward trend in the demand for advanc
Dyson
06/07/2025
Regarding the transformation of permanent magnet circuit breakers in the 35kV switch room of 110kV substation in Luliang Oilfield
Regarding the transformation of permanent magnet circuit breakers in the 35kV switch room of 110kV substation in Luliang Oilfield
I. Equipment Dilemmas in Freezing WintersThe 35kV switch room of the 110kV substation in Luliang Oilfield, commissioned in 2002, has always been a key area for my maintenance team. The original ZN23-40.5/1600 vacuum circuit breakers, equipped with spring operating mechanisms, posed recurring challenges during subzero winters. With over 200 components and a 12-stage mechanical linkage, the spring mechanisms suffered severe wear on sliding friction surfaces. In temperatures as low as -40°C, lu
Echo
06/07/2025
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
VS1 - Type Indoor High - Voltage Vacuum Circuit BreakerThe VS1 - type indoor high - voltage vacuum circuit breaker is an indoor device for three - phase AC 50Hz with a rated voltage of 12kV. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants, and substations. The circuit breaker arranges the main circuit and the operating mechanism on a special - shaped frame in a front - rear manner, that is, an integral layout. This structural
Echo
06/06/2025
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
ZN63A Indoor AC High-Voltage Vacuum Circuit BreakerThe ZN63A indoor AC high-voltage vacuum circuit breaker is a three-phase AC 50 Hz, 12 kV indoor device, used for starting, stopping, controlling, and protecting high-voltage motors of 10,000-ton free forging presses. AC high-voltage vacuum circuit breakers play a critical role in enterprise production. Timely and accurate resolution of their faults to quickly restore production is essential for enterprise development. During the start/stop of hi
Felix Spark
06/06/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放