• 1~10kV Overhead Insulated Cable
1~10kV Overhead Insulated Cable
discuss personally
Model
JKV-10
JKV-1
Basic info
Brand Wone
Model NO. Overhead insulated conductors
Rated voltage 0.6/1kV
Series JKY/JKV
Product Detail

Description

The so-called overhead line is a relative cable, which is a line that transmits electric energy by the tower to erect the conductor at a certain height. For the high-voltage transmission and distribution network overhead line insulation is generally air, the previous distribution line (10kV below 380V) generally also uses bare wire, but due to the complex urban distribution environment.

Standard

This product is produced according to the standard of GB/T12527-2008 "Overhead Insulated Cable with Rated Voltage of 1kV and Below".

Scope of application

It is applicable to overhead power lines with rated voltage of 10KV and below.

Features

  • The rated voltage is 0.6/1KV, 10KV.

  •  The cable laying temperature should not be lower than 0°C.

  •  The maximum temperature of the cable in the event of a short circuit (the longest duration is not more than 5s): 160 °C for polyethylene insulation, 250 °C for cross-linked polyethylene insulation .

  •  The long-term allowable working temperature of the cable conductor: polyvinyl chloride insulation should not exceed 70 °C, and cross-linked polyethylene insulation should not exceed 90 °C.

  •  Allowable bending radius of the cable: The allowable bending radius of the cable should not be less than the diameter of the cylinder used in the cable bending test.

Product Model

  •  0.6/1KV series: JKV, JKLV, JKY, JKLY, JKYJ, JKLYJ, 16~240mm2.

  •  10KV series: JKYJ, JKLYJ, JKY, JKLY, JKLYJ/B, JKLYJ/Q, JKLYJ/Q, 10~300mm2.

Structure Size and technical parameter

参数.png

参数.png


Q: What kind of cable is the JKY/JKLY cable? 

A: JKY/JKLY cable cable is copper core (aluminum core) polyethylene insulated overhead cable. 

Q: What are the characteristics of JKY/JKLY? 

A: Its copper core (aluminum core) has good electrical conductivity and can efficiently transmit current. The polyethylene insulation layer has good insulation performance and can effectively prevent the occurrence of leakage. JKY cable structure is relatively simple, light weight, easy to install and erect, suitable for use in overhead lines. At the same time, it has a certain ability to adapt to the environment, and can work stably under normal climate and environmental conditions. 

Q: What scenarios are JKY cables mainly used in? 

A: JKY cable is mainly used in overhead power transmission scenarios, such as in rural power grid construction, because of its relatively low cost and can meet the basic power transmission needs, it is widely used in power transmission lines from substations to villages. It is also often used in small industrial parks or power distribution lines around towns.

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放