• LSZ Current Transformer
LSZ Current Transformer
discuss personally
Model
LSZ-300/5
Basic info
Brand Wone Store
Model NO. LSZ Current Transformer
Rated frequency 50/60Hz
Power frequency withstand voltage 3kV
Rated current ratio 300/5
Series LSZ
Product Detail

Product Overview

Ring Main Unit C-GIS Three-Phase The three-phase CT is full-enclosed in the flame retardant plastic shells, primary bushing or cable can pass through the inner hole, bottom has installation inserts for fixation. It is simple and shortcut, is suitable for measuring current, signal collection and protective relaying in the medium voltage power system of bushing or cable etc.

Key Features

  •  Fully Sealed Epoxy Cast Insulation:Vacuum-cast IP68-rated enclosure allows continuous submersion up to 1 meter underwater. Insulation material meets UL94 V-0 flame retardancy, withstanding -40°C to +120°C thermal cycling and UV aging resistance. Ideal for harsh environments including coastal areas, deserts, and chemical plants.
  •  Wide-Range Multi-Tap Configuration:Covers ratios from 50/5 to 4000/5A with four built-in tap windings (e.g., 200/5A, 400/5A, 800/5A, 1600/5A), switchable via pluggable links. Dynamic response ratio of 1:200 maintains linearity from 0.5% rated current to short-circuit current (20kA).
  • Ultra-Low Power Consumption & Energy Saving Design:No-load loss ≤0.8VA, load loss ≤0.2VA, reducing energy consumption by 40% compared to conventional CTs. Secondary windings use high-conductivity oxygen-free copper with 30% increased cross-sectional area to minimize heat generation and losses.
  •  Fast Transient Response Characteristics:Special magnetic circuit design prevents core saturation under short-circuit 冲击 with remanence coefficient ≤10%. Protection winding response time ≤8ms, providing reliable signals for high-speed protection systems such as differential and distance relays.

Technical Data

  • Rated secondary current:  5A,1A
  • Power frequency withstand voltage: 3kV
  • Rated frequency:  50/60Hz
  • Installation site:  Indoor
  • Technical standard:  IEC 60044-1 (IEC 61869-1&2)

Specification

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
In UHV GIS, current transformers are key to electric energy metering. Their accuracy determines power trade settlements, so on - site error verification perJJG1021 - 2007is needed. On - site, use power supplies, voltage regulators, and current boosters. Due to encapsulation in GIS, build test circuits via exposed grounding knives, bushings, and return conductors; right circuits simplify wiring and boost accuracy.Challenges like large test current, long circuits, and high impedance exist, but rea
Oliver Watts
07/07/2025
What are the polarity test methods for GIS current transformers?
What are the polarity test methods for GIS current transformers?
I’m Oliver, an 8 - year current transformer testing pro. Today, let’s break down new and old polarity test methods for GIS current transformers—how they work and their pros/cons.1.Testing Methods1.1New MethodPre - test ops: Open FDS21/FDS22 fast disconnectors + DS23 disconnector. Close CB21 breaker, then ES21/ES22 grounding disconnectors. Disconnect ES21’s SF6 - shell ground.Wiring: Connect battery between ES21’s moving contact (negative grounded) + ground electrode
Oliver Watts
07/07/2025
Exploring the Design and Application of Photoelectric Current Transformers in GIS
Exploring the Design and Application of Photoelectric Current Transformers in GIS
1.Design and Application Example of Photoelectric Current Transformer in GISThis article takes a 126kV GIS project as a specific example to deeply explore the design ideas and practical application of photoelectric current transformers in the GIS system. Since this GIS project was officially put into operation, the power system has remained stable, with no major failures occurring, and the operation status is relatively ideal.1.1 Design and Application Ideas of Photoelectric Current TransformerI
Dyson
07/07/2025
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
I'm Oliver, with 8 years of experience in current transformer testing. These are all practical experiences, shared with you1 Maintenance of Current TransformersHaving been in the business of current transformer testing for 8 years, I know a thing or two about their maintenance! The maintenance of current transformers is divided into minor repairs, intermediate repairs, and major overhauls.Minor repairs mainly involve opening the cover (if necessary) and changing the oil, usually carried out once
Oliver Watts
07/07/2025
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
Gas - insulated switchgear (GIS) , often called “SF6 combined electrical apparatus”, is widely used in power systems for its high reliability, small footprint, low noise, and low loss. It encloses high - voltage devices like circuit breakers, fast grounding switches, current transformers, and busbars in a grounded metal shell filled withSF6gas. Each device sits in a separate gas chamber with different pressures. The CT terminal block divides gas chambers, connects components, and eas
Felix Spark
07/07/2025
×