Basic info
Brand Vziman
Model NO. Non-encapsulated H-class Dry-type Power Transformers 800KVA 1000KVA 1250KVA 1600KVA 2000KVA 2500KVA
Rated capacity 2500kVA
Voltage grade 10KV
Series SGB
Product Detail

Description:
The SG(B)10 series non-encapsulated H-class dry-type power transformers integrate German (MORA) dry-type transformer process technology, ensuring full compliance with fireproof, waterproof, and environmental protection standards. Engineered as ideal solutions for distribution systems, they excel in safety-critical applications, including subways, shipbuilding, mining, chemical industries, power utilities, and personnel-dense buildings, as well as environments with special safety requirements.

Feature

  • Maintenance-free Design: The non-encapsulated windings allow direct visual inspection, eliminating the need for preventive tests. This extends the maintenance cycle to 5 years and reduces the full life-cycle cost by 30%.

  • Intelligent Monitoring Integration: Equipped with built-in winding temperature sensors and RS485 communication interfaces, it supports remote monitoring and early warning. The fault response time is shortened to seconds, significantly reducing operational and maintenance costs.

  • Superior Insulation and Heat Dissipation Performance: Adopts H-class insulation materials (temperature resistance up to 180℃), combined with non-encapsulated open-winding design, which enhances heat dissipation efficiency by 30%. It can stably operate under 150% rated capacity overload, perfectly suitable for high-load fluctuation working conditions.


Model and Meaning:

企业微信截图_17230768291792.png

Parameter:


image.png


Notes: The Dimension and weight will be changed according to the requirements.


What is an Unencapsulated Class H Dry-Type Power Transformer?

Basic Definitions:

  • Non-encapsulated: It means that the coils of the transformer are not subjected to the traditional encapsulation treatment but are directly exposed to the air. This design can improve the heat dissipation efficiency and extend the service life.

  • H-Class Insulation: H-Class insulation materials refer to those insulation materials that can withstand a maximum temperature of 180°C. They possess excellent heat resistance and electrical properties.

Structural Characteristics:

  • Coil Structure: The non-encapsulated structure is adopted, with the coils being directly exposed to the air, which is beneficial for heat dissipation.

  • Insulation Materials: H-Class insulation materials such as NOMEX paper and fiberglass are used, featuring excellent heat resistance and electrical properties.

  • Iron Core: It is usually made of laminated high-quality silicon steel sheets, with the characteristics of low loss and low noise.

  • Cooling Methods: Generally, natural air cooling (AN) or forced air cooling (AF) is employed. The appropriate cooling method is selected according to specific application requirements.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry