• Non-encapsulated H-class Dry-type Power Transformers 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA
Non-encapsulated H-class Dry-type Power Transformers 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA
discuss personally
Model
SGB10-10KV-2500KVA
SGB10-10KV-2000KVA
SGB10-10KV-1600KVA
SGB10-10KV-1250KVA
SGB10-10KV-1000KVA
SGB10-10KV-800KVA
Basic info
Brand Vziman
Model NO. Non-encapsulated H-class Dry-type Power Transformers 800KVA 1000KVA 1250KVA 1600KVA 2000KVA 2500KVA
Rated capacity 2000kVA
Voltage grade 10KV
Series SGB
Product Detail

Description:
The SG(B)10 series non-encapsulated H-class dry-type power transformers integrate German (MORA) dry-type transformer process technology, ensuring full compliance with fireproof, waterproof, and environmental protection standards. Engineered as ideal solutions for distribution systems, they excel in safety-critical applications, including subways, shipbuilding, mining, chemical industries, power utilities, and personnel-dense buildings, as well as environments with special safety requirements.

Feature

  • Maintenance-free Design: The non-encapsulated windings allow direct visual inspection, eliminating the need for preventive tests. This extends the maintenance cycle to 5 years and reduces the full life-cycle cost by 30%.

  • Intelligent Monitoring Integration: Equipped with built-in winding temperature sensors and RS485 communication interfaces, it supports remote monitoring and early warning. The fault response time is shortened to seconds, significantly reducing operational and maintenance costs.

  • Superior Insulation and Heat Dissipation Performance: Adopts H-class insulation materials (temperature resistance up to 180℃), combined with non-encapsulated open-winding design, which enhances heat dissipation efficiency by 30%. It can stably operate under 150% rated capacity overload, perfectly suitable for high-load fluctuation working conditions.


Model and Meaning:

企业微信截图_17230768291792.png

Parameter:


image.png


Notes: The Dimension and weight will be changed according to the requirements.


What is an Unencapsulated Class H Dry-Type Power Transformer?

Basic Definitions:

  • Non-encapsulated: It means that the coils of the transformer are not subjected to the traditional encapsulation treatment but are directly exposed to the air. This design can improve the heat dissipation efficiency and extend the service life.

  • H-Class Insulation: H-Class insulation materials refer to those insulation materials that can withstand a maximum temperature of 180°C. They possess excellent heat resistance and electrical properties.

Structural Characteristics:

  • Coil Structure: The non-encapsulated structure is adopted, with the coils being directly exposed to the air, which is beneficial for heat dissipation.

  • Insulation Materials: H-Class insulation materials such as NOMEX paper and fiberglass are used, featuring excellent heat resistance and electrical properties.

  • Iron Core: It is usually made of laminated high-quality silicon steel sheets, with the characteristics of low loss and low noise.

  • Cooling Methods: Generally, natural air cooling (AN) or forced air cooling (AF) is employed. The appropriate cooling method is selected according to specific application requirements.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the polarity test methods for GIS current transformers?
What are the polarity test methods for GIS current transformers?
I’m Oliver, an 8 - year current transformer testing pro. Today, let’s break down new and old polarity test methods for GIS current transformers—how they work and their pros/cons.1.Testing Methods1.1New MethodPre - test ops: Open FDS21/FDS22 fast disconnectors + DS23 disconnector. Close CB21 breaker, then ES21/ES22 grounding disconnectors. Disconnect ES21’s SF6 - shell ground.Wiring: Connect battery between ES21’s moving contact (negative grounded) + ground electrode
Oliver Watts
07/07/2025
Exploring the Design and Application of Photoelectric Current Transformers in GIS
Exploring the Design and Application of Photoelectric Current Transformers in GIS
1.Design and Application Example of Photoelectric Current Transformer in GISThis article takes a 126kV GIS project as a specific example to deeply explore the design ideas and practical application of photoelectric current transformers in the GIS system. Since this GIS project was officially put into operation, the power system has remained stable, with no major failures occurring, and the operation status is relatively ideal.1.1 Design and Application Ideas of Photoelectric Current TransformerI
Dyson
07/07/2025
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
I'm Oliver, with 8 years of experience in current transformer testing. These are all practical experiences, shared with you1 Maintenance of Current TransformersHaving been in the business of current transformer testing for 8 years, I know a thing or two about their maintenance! The maintenance of current transformers is divided into minor repairs, intermediate repairs, and major overhauls.Minor repairs mainly involve opening the cover (if necessary) and changing the oil, usually carried out once
Oliver Watts
07/07/2025
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
Gas - insulated switchgear (GIS) , often called “SF6 combined electrical apparatus”, is widely used in power systems for its high reliability, small footprint, low noise, and low loss. It encloses high - voltage devices like circuit breakers, fast grounding switches, current transformers, and busbars in a grounded metal shell filled withSF6gas. Each device sits in a separate gas chamber with different pressures. The CT terminal block divides gas chambers, connects components, and eas
Felix Spark
07/07/2025
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!