Brand | Wone |
Model NO. | GW6B Series Switch Disconnector |
Rated voltage | 126KV |
Rated normal current | 3150A |
Rated frequency | 50/60Hz |
Rated peak value withstand current | 125kA |
Rated short-time withstand current | 50kA |
Series | GW6B Series |
Product introduction
GW6B Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs is changed, In addition, it can be used to exercise safe electrical insulation for such HV electric
apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.
This product is of the single-post bi-arm vertical telescope type (scissor-type) and suitable for the bus's Switch Disconnector. It can be laid out directly under the bus, thus occupying a small area. It’s effect of saving energy can be prominent at the substation where double bus lines are accompanied by the bypass bus.
The Switch Disconnector is accompanied by a JW10 earthing switch which will be used for the bus grounding at the lower layer, The grounding of the bus line at the upper layer requires the use of an independent earthing switch. 363kV and 550Kv Switch Disconnector and earthing switch are equipped with the SRCJ8 motor actuator for the single pole operation. Meanwhile, the tri-pole linkage can be achieved. The 126kV and 252kV Switch Disconnector adopt SRCJ3 motor-based actuator to realize the tri-pole linkage. The earthing switch adopts SRCS manual actuator to actualize tri-pole linkage.
This Switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internally level of the same kinds of products
GWGB Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator, operating insulator and conducive part., The conductive pat includes the gear box and foldable conductive am fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.
The actuator dives the operating insulator, and through the four link lever-driven scissor-type conductive arm, lift and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line, to open or close the Switch Disconnector. After the closing, a vertical insulating break will be formed.
Main characteristic
1、 Superior conductance system; With open structure, conductor is laid out in the middle of the transmission base while the main rod and reverse connecting rod are installed outside. Balancing spring is sealed with aluminum cover and transmission parts needing debugging are exposed for easy installation and debugging. dust prevention. Add a dustcover to bearing and adopt seal structure externally.
2、 Contact forceps can cover a large area of rated contact, This product is in the double arm telescopic (scissor-type) structure. The forceps of the moving contact cover a large area of rated contact, particularly applicable to soft bus line, and also to hard bus line.
3、 Open gear box, which has a good visibility, is convenient for installation, debugging and maintenance. The main crank arm is combined with operating flange to reduce he transmission link and the height of transmission base, which can improve the transmission efficiency and reliability. The rotation shat is designed as double bearing structure so that the transmission is flexible and reliable.
4、 Structural design: the separation of machines from power. The design concept is the separation of machines from power, that is, the conductive elements, springs and mechanic driving elements are mutually isolated to prevent current from passing through springs and mechanical driving elements. in this way, the stability of the driving elements can be enhanced.
5、 Provide one key sequential control "double confirmation" function expansion.
Main technical parameters
Order notice
Product model, rated voltage, rated current, rated short-lime withstand current and creepage distance must be specified at the goods-ordering time;
It must be decided whether a earthing switch should be attached to the Switch Disconnector;it must be decided whether the upper bus line of the Switch Disconnector is soft or hard.
Additionally, the external diameter of the tubular busbar shall be specified;
It must be decided whether the Switch Disconnector is arranged in cross-over or parallel form;
The actuator's model and name, motor's voltage, control voltage and the number of contacts for auxiliary switch