• DS4C 252kV High voltage disconnect switch
DS4C 252kV High voltage disconnect switch
discuss personally
Model
DS4C-252/4000-50
DS4C-252/3150-50
DS4C-252/2500-50
DS4C-252/1600-50
Basic info
Brand ROCKWILL
Model NO. DS4C 252kV High voltage disconnect switch
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS4C
Product Detail

Product introduction:

GW4C Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs Is changed. In addition, It can be used lo exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product has two insulators with horizontal center breaks. It Is openable In the middle and accessible to the grounding switch on one side or two sides. The disconnect switch adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage,The earthing switch adopts CS14G manual operating mechanism to actual亿e tri-pole linkage

This product has been verified by the Chinese competent authority as having uniqueness in design and reaching intonational advanced level of similar products.

GW4C disconnect switch comprises three single poles and operating mechanism. Each single pole is made of a base, post insulator and conductive part revoting insulating posts are mounted at both sides of a long base. The conductive switch blade's contact arms are respectively fixed at the tops of the insulating posts.

When the Insulating post at one end of the actuator revolves to drive, and through the cross-over lever, brings the insulating post at the other end to rotate reversely by 90° to make the conductive switch blade circumgyrate. In this way, the isolating switch is opened and closed.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight targe radiation area and strong stance against corruption
  • The finger is made of pure copper and has a silver plating process. It has strong now capacity and long mechanical life. The stamping process ensures the reliability of contact and finger contact.
  • The contact finger pressure is prohormonal to the primary insertion depth of the contact, the sensitivity is low, the contact insertion area is long, the on-site debugging is difficult, and the product is highly reliable against adverse interference such as harsh environment (winding of the flexible wire).
  • The contact Is made of curved copper plate. In the opening and closing processes, there is a short trip of friction between the contact and the finger and the required operating force is small.
  • The rotating parts of the Switch Disconnector are designed to be free of any maintenance. The rotating base is designed into a closure structure which denies t沺access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden.
  •  Provide one-key sequential control "double confirmation" function expansion

Main technical parameters:

GW4C-parameters.png

 Order notice: 

Product model, rated voltage, rated current, Rated short-time withstand current and creepage distance must be specified at the goods-ordering time.

The disconnect switch offers several options of grounding (Left, right, both left and right).Unless otherwise specified, the goods supplied will be considered as providing the option of right grounding;

Note:

  • The methods of judging left end right grounding: hold out both arms and keep the arms in the same direction as the disconnect switch is opened. The earthing switch will be considered as left grounding non the left hand side, and right grounding if on the right hand side;
  • The operating mechanism, motor voltage, control voltage and the number of contacts for auxiliary switch;
  • When the Switch Disconnector is used at the incoming and outgoing terminals of the substation in the double loop parallel overhead power transmission line, if the earthing switch requires the opening/dosing induction current then such requirement shall be specified. Besides, the parameters and the side at which the earthing switch Is set shall be defined. (Special notice: Not all earthing switches attached to the earthing switches and disconnect switches at the substation shall require the opening/closing Induction current)

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What does the recloser testing process in Nigeria involve?
What does the recloser testing process in Nigeria involve?
The testing of reclosers in Nigeria is a rigorous, multi-stage process designed to ensure compliance with local regulations, adaptability to harsh environmental conditions, and reliable operation across diverse grid landscapes. Below is an in-depth exploration of the key testing phases and their technical implications:1. Regulatory Compliance: SONCAP Certification and NERC StandardsReclosers entering Nigeria’s market must first navigate mandatory regulatory hurdles. SONCAP certification in
Oliver Watts
06/04/2025
What are the key considerations for recloser selection in Nigeria?
What are the key considerations for recloser selection in Nigeria?
When selecting reclosers for power distribution networks in Nigeria, several critical factors must be addressed to ensure reliable, efficient, and compliant operation. Here's a breakdown of key considerations:1. Voltage Compatibility: 11kV StandardsNigeria’s distribution grid widely operates at the 11kV voltage level. Reclosers must be rated for 11kV to seamlessly integrate into the network. This ensures they can handle the system’s voltage demands, whether in urban, rural, or indust
James
06/04/2025
How does the merger device achieve distribution network feeder automation?
How does the merger device achieve distribution network feeder automation?
AC High - Voltage Automatic Recloser (Recloser for Short in This Article)The AC high - voltage automatic recloser (referred to as the recloser for short in this article) is a high - voltage switchgear with self - control (it has the functions of fault current detection, operation sequence control and execution by itself, without the need for additional relay protection and operation devices) and protection functions. It can automatically detect the current and voltage passing through the main ci
Echo
06/04/2025
Short Circuit Ratio of a Synchronous Machine
Short Circuit Ratio of a Synchronous Machine
The Short Circuit Ratio (SCR) of a Synchronous MachineThe Short Circuit Ratio (SCR) of a synchronous machine is defined as the ratio of the field current needed to generate rated voltage under open-circuit conditions to the field current required to sustain rated armature current during a short-circuit condition. For a three-phase synchronous machine, the SCR can be derived from its Open-Circuit Characteristic (O.C.C) at rated speed and Short-Circuit Characteristic (S.C.C), as illustrated in the
Edwiin
06/04/2025
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
1. IntroductionIn Vietnam's coastal regions, 20kV reclosers play a critical role in maintaining power supply reliability amid harsh environmental conditions. These devices, compliant with IEC 62271-111 and Vietnam's national standard TCVN, are frequently exposed to salt fog, high humidity, and typhoons, necessitating robust fault management strategies. This article explores typical malfunctions of IP67-rated reclosers in Vietnam and proposes integrated solutions to enhance grid resilience.2. Env
Felix Spark
06/03/2025
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
1. IntroductionIn the modern power grid infrastructure, high - voltage reclosers play a pivotal role in enhancing the reliability and efficiency of power supply. This is particularly crucial in regions like Indonesia, which has a vast and complex power distribution network spanning numerous islands, and Vietnam, with its developing coastal power systems. The 20kV voltage level, falling within the medium - high - voltage range, is widely adopted in urban grids, industrial power supply, and certai
Dyson
06/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!