• DS17 126kV 252kV 363kV 420kV 800kV High voltage disconnect switch
DS17 126kV 252kV 363kV 420kV 800kV High voltage disconnect switch
discuss personally
Model
DS17-800/5000-63
DS17A-550/4000-63
DS17B-550/3150-50
DS17B-420/3150-50
DS17A-363/5000-63
DS17A-363/3150-50
DS17B-252/5000-63
DS17B-252/3150-50
DS17B-126/3150-40
DS17B-126/2500-40
Basic info
Brand ROCKWILL
Model NO. DS17 126kV 252kV 363kV 420kV 800kV High voltage disconnect switch
Rated voltage 126kV
Rated normal current 2500A
Series DS17
Product Detail

Description:

DSDS17 series disconnector adopts double-column horizontal telescopic structure, mainly composed of base, insulator, conductive system, operating mechanism, etc. The disconnector is operated by CJ11 type motor operating mechanism for opening and closing. The attached ground switch is mainly composed of ground switch system and operating mechanism, and each group of ground switches is operated by a CJ11 motor operating mechanism for opening and closing.


Main Features:

  •  Strong product flow capacity, long mechanical life.

  • The transmission shaft of the product is made of high quality alloy steel, the outer surface is treated with hot dip galvanizing, and the anti-corrosion ability is strong; The shaft sleeve is made of high-strength engineering plastic, which has good wear resistance and strong anti-corrosion property.

  • The product adopts a fully sealed structure between the moving contact base and the contact finger, effectively avoiding the intrusion of rain, snow and frost, and has strong waterproof ability.

  • The contact surface of the product adopts advanced silver plating technology, and the hardness of the silver layer reaches 140HV, which enhances the electrical conductivity and wear resistance of the surface.

Technical parameter

 

image.png

image.png

What are the application scenarios of disconnectors?

In substations, isolator switches are essential equipment. They are used to isolate busbars of different voltage levels from lines, transformers, and other equipment. For example, in 110 kV or 220 kV substations, isolator switches are installed at the connection points of incoming lines, outgoing lines, and transformers, playing a crucial role during equipment maintenance and switching operations.

Industrial Enterprise Distribution Systems:

In the distribution systems of industrial enterprises, isolator switches are used to isolate power connections between different workshops and equipment groups. When a particular workshop or equipment group needs maintenance or inspection, the isolator switch can be used to isolate it from the power supply without affecting the normal operation of other workshops or equipment groups. Additionally, in internal power line switching operations within the enterprise, isolator switches can be used in conjunction with other switching devices.

Transmission Lines of Power Systems:

At switching stations and substations where transmission lines connect, isolator switches are installed to manage the connection, disconnection, and maintenance of the lines. For example, on high-voltage transmission line towers, isolator switches can be installed below the insulator strings to facilitate line maintenance and inspection. They can also be used to isolate the lines from the busbars of the substation when necessary.


 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放