• 625-650 Watt bifacial module with dual glass
625-650 Watt bifacial module with dual glass
discuss personally
Model
SP-640-BDV
SP-635-BDV
SP-630-BDV
SP-625-BDV
Basic info
Brand Wone
Model NO. 78HL4-BDV 625-650 Watt BIFACIAL MODULE WITH DUAL GLASS
Maximum Power 625Wp
Series 78HL4-BDV
Product Detail

Certification

  • IEC61215:2021 / IEC61730:2023 ·

  •  IEC61701 / IEC62716 / IEC60068 / IEC62804 · 

  • ISO9001:2015: Quality Management System · 

  • ISO14001:2015: Environment Management System ·

  •  ISO45001:2018: Occupational health and safety management systems.

Features

  • N-type modules with Tunnel Oxide Passivating Contacts (TOPcon) technology offer lower LID/LeTID degradation and better low light performance.

  • N-type modules with JinkoSolar's HOT 3.0 technology offer better reliability and efficiency.

  • Dual-sided power generation gain increases with backside exposure to light, significantly reducing LCOE.

  • Certified to withstand: 5400 Pa front side max static test load 2400 Pa rear side max static test load.

  • Better light trapping and current collection to improve module power output and reliability.

  • Minimizes the chance of degradation caused by PID phenomena through optimization of cell production technology and material control.

image.png


Mechanical Characteristics

image.png

Packaging Configuration

image.png

Specifications (STC)

image.png

Specifications (BNPI)

image.png

Application Conditions

image.png

Engineering Drawings

image.png

*Note: For specific dimensions and tolerance ranges, please refer to the corresponding detailed module drawings.

Electrical Performance & Temperature Dependence

image.png

image.png

What is a solar bifacial module?

Solar bifacial modules are solar panels capable of absorbing light from both sides (that is, the front and the back) and converting it into electrical energy. Compared to traditional monofacial solar modules, bifacial modules have a higher potential for energy output, as they can not only capture the sunlight directly shining on them but also absorb light reflected from the ground as well as scattered light from the surroundings.

Working Principle of Bifacial Modules:

  • Front Side Absorption: The front side works like traditional solar modules, absorbing direct sunlight through the solar cells and converting it into electrical energy.

  • Back Side Absorption: The back side is also covered with a layer of solar cells that can absorb sunlight reflected from the ground as well as scattered light from the surroundings.

  • Light Trapping: The reflectivity of the ground affects the power generation efficiency of the back side of bifacial modules. Ground surfaces that are white or light in color have higher reflectivity, providing more reflected light to the solar cells on the back side.

  • Environmental Impact: The installation environment can also affect the performance of bifacial modules. For example, different surfaces such as grasslands, snow-covered areas, or rooftops will have varying levels of reflectivity and amounts of scattered light.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
A Novel Detection Method for Stuck Faults in Load Switches
A Novel Detection Method for Stuck Faults in Load Switches
In recent years, as distribution automation advances, load switches see wider use in distribution lines. Yet, mechanical - failure - induced accidents are on the rise, burdening line operation and maintenance.Poor mechanical performance is the main cause of switch faults. Many scholars study large - scale switchgear operation, using methods like coil current detection, vibration signal analysis, switch travel testing, ultrasonic flaw detection, and infrared thermometry. Motor - current - based s
Oliver Watts
06/30/2025
What You Need to Know About Load Switch Malfunctions
What You Need to Know About Load Switch Malfunctions
Hey there, I’m Blue — been working as an electrical engineer for more than 20 years now.I’ve spent most of my career designing circuit breakers, managing transformers, and helping power companies solve all sorts of electrical system challenges.Today, a friend from Southeast Asia asked me:"What are the common faults of load switches?"Great question! So let’s break it down in simple terms — no fancy jargon, just real-world stuff you might actually see on the job or during maintenance.First, What E
Master Electrician
06/30/2025
What tests need to be conducted for load switches?
What tests need to be conducted for load switches?
As a technician with years of on-site experience in power testing, I understand the importance and complexity of load switch testing. Below, I combine practical work experience to elaborate on the full process of load switch testing, from testing items and methods to equipment and procedural specifications.I. Routine Electrical Performance Testing(1) Loop Resistance TestLoop resistance is a core indicator for evaluating a load switch's conductivity. I strictly follow GB/T 3804 and GB 1984 standa
Oliver Watts
06/28/2025
What are the common faults of load switches?
What are the common faults of load switches?
As an on-site maintenance technician, I frequently deal with electrical, mechanical, and insulation faults in load switches. The following outlines fault manifestations, causes, and solutions:I. Electrical Fault Handling(1) Contact HeatingContact heating is mainly caused by poor contact, insufficient pressure, or three-phase asynchrony. When the contact resistance exceeds 1.5 times the initial value, the temperature rise will exceed the standard in a 40℃ environment. For example, the FW4-10 swit
Felix Spark
06/28/2025
Short-Circuit Fault Analysis of 10kV Puffer-Type Load Switch
Short-Circuit Fault Analysis of 10kV Puffer-Type Load Switch
1. Fault OverviewIn June 2013, a fault occurred in a high - voltage switchgear in operation in a certain urban area, causing a 10kV line to trip. On - site investigation revealed that the faulty switchgear was a pneumatic ring - network high - voltage load switchgear (HXGN2 - 10 type), and the fault characteristic was athree - phase arc short circuit. After isolating the fault and restoring power supply to users, it should be noted that the same type of switchgear in this area, which was put int
Felix Spark
06/28/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!