• 72.5kV HV SF6 circuit breaker
72.5kV HV SF6 circuit breaker
discuss personally
LW36-72.5(W)/T5000-50
LW36-72.5(W)/T4000-50
LW36-72.5(W)/T4000-40
LW36-72.5(W)/T3150-40
Basic info
Brand Wone
Model NO. 72.5kV HV Gas circuit breaker
Rated voltage 72.5KV
Rated normal current 4000A
Rated frequency 50Hz
Rated short circuit breaking current 50kA
Series LW36-72.5
Product Detail

Product introduction:

LW36-72.5 self-energy outdoor HV AC sulfur hexafluoride circuit breaker is an outdoor three-phase porcelain column electrical equipment mainly used in AC 50Hz or 60Hz, 72.5kV electricity systems in extremely cold regions (for electric stations in general regions and -42'℃ extremely cold regions). This product can be operated frequently and used as a connection circuit breaker.

Main characteristic:

  • High performance -strong rated circulating ability: strong short circuit breaking ability up to 5500A. 50kA.

  • Long service life -electrical endurance: 50kAx21times; mechanical life: 10000 times.

  • Reliable breaking performance.

  •  Reliable sealing performance; Annual leakage of SF6 gas ≤0.5%.

  • Meeting the requirements of hard running environments -suitable for Class IV polluted environments.

  • Multi-structure forms-usually porcelain column type and handcart type.

Main technical parameters:

1732520755584.png

Instructions on placing orders :  

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store motor and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

How to choose the right type of circuit breaker?

System Voltage:

  • System Voltage: Determine the working voltage of the system and select a circuit breaker that can withstand the voltage level. High-voltage and ultra-high-voltage systems typically use SF6 gas or oil-immersed circuit breakers.

System Current:

  • System Current: Consider the maximum continuous current and short-circuit current of the system, and select a circuit breaker with sufficient rated current and short-circuit capacity.

Application Environment:

Outdoor Environment:

  • Outdoor Environment: If the circuit breaker will be installed outdoors, consider its performance in resisting pollution, moisture, and windblown sand. Tank-type circuit breakers (such as those using SF6 gas or oil) are generally more suitable for outdoor environments.

Indoor Environment:

  • Indoor Environment: For indoor installations, circuit breakers that are smaller in size and easier to maintain can be chosen, such as vacuum circuit breakers.

Insulating and Arc-Quenching Medium:

SF6 Gas:

  • SF6 Gas: Offers excellent insulating and arc-quenching performance, making it suitable for high-voltage and ultra-high-voltage systems. However, environmental concerns and leakage issues need to be addressed.

Insulating Oil:

  • Insulating Oil: Provides good insulating and heat dissipation properties, but poses fire risks and environmental pollution issues. It is suitable for applications where fire prevention requirements are not stringent.

Vacuum:

  • Vacuum: Suitable for medium and low-voltage systems, offering long life, high reliability, and ease of maintenance.


Other recommendations