• 640 W - 670 W Bifacial high-power Dual cell PERC module (mono)
  • 640 W - 670 W Bifacial high-power Dual cell PERC module (mono)
640 W - 670 W Bifacial high-power Dual cell PERC module (mono)
discuss personally
Model
WN7N-640MB-AG
Basic info
Brand Wone
Model NO. 640 W - 670 W Bifacial high-power Dual cell PERC module (mono)
Power Bifaciality 70%
Max. System Voltage 1500V (IEC)
Max. Series Fuse Rating 35 A
Module Fire Performance CLASS C
Max. power of the module 670 W
Max. efficiency of Module 21.6 %
Series Bifacial MONO PERC
Product Detail

Features

  • Module power up to 670 W Module efficiency up to 21.6 %.

  • Up to 8.9 % lower LCOE Up to 4.6 % lower system cost.

  • Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation.

  • Compatible with mainstream trackers, cost effective product for utility power plant.

  • Better shading tolerance.

Standard

  • 40 °C lower hot spot temperature, greatly reduce module failure rate.

  • Minimizes micro-crack impacts.

  • Heavy snow load up to 5400 Pa, wind load up to 2400 Pa*.

Engineering drawing(mm)

image.png

CS7N-650MB-AG / I-V gurves

image.png

Electrical date/STC*

企业微信截图_17301819004341.png


Electrical date/NMOT*

image.png

Electrical date

image.png

Mechanical charactheristics

image.png

Temperature characteristics

image.png

What is LCOE?

LCOE (Levelized Cost of Energy) refers to the levelized cost of electricity. It is a method used to evaluate the average cost of a power plant throughout its entire life cycle. LCOE takes into account all the expenses of the power plant's construction and operation and apportions them to each unit of electricity produced, thereby measuring the economic viability of a power generation project.

Calculation Formula:

The basic calculation formula for LCOE is as follows:

LCOE = Present Value of Total Costs / Present Value of Total Electricity Generation

Among them, the "Present Value of Total Costs" includes the sum of all costs after discounting, such as construction costs, operation and maintenance costs, fuel costs, decommissioning costs, etc.; the "Present Value of Total Electricity Generation" is the value after discounting of the total electricity generated by the power plant throughout its entire life cycle.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
In which directions will dry-type transformers develop in the future?
In which directions will dry-type transformers develop in the future?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From my early days doing commissioning and maintenance in distribution rooms, to later participating in electrical system design and equipment selection for large-scale projects, I’ve witnessed how dry-type transformers have evolved from traditional tools into smarter, greener devices.Recently, a new colleague asked me:“What’s the current state of dry
Echo
07/02/2025
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!