Model
SFL11-4000/10
Basic info
Brand Vziman
Model NO. 4000KVA 10KV Electric Furnace Transformer
Rated capacity 4000KVA
Voltage grade 10KV
Series Electric Furnace Transformer
Product Detail

Product overview:

  •  Electric furnace transformer is a professional transformer planned according to various electric furnace working principle, load characteristics and operation characteristics.

  • It includes: arc furnace transformer for steelmaking, ladle refining furnace transformer, slag furnace transformer, mineral heat furnace transformer, power frequency furnace transformer and other communication furnace transformer and medium frequency induction furnace transformer, silicon carbide, graphitization furnace transformer and other DC furnace transformer.

  • Industrial furnace transformers are mainly divided into 3 types: resistance furnace transformers, arc furnace transformers and induction furnace transformers.

  • Hengfengyou electric furnace transformer production standards: one is according to the current provisions of China's standard planning and production of standard electric furnace transformer; The other is a new type of energy-saving furnace transformer developed and manufactured on the basis of Chinese standard furnace transformer.

Main applications:

  •  In metallurgical industry, it is used for smelting high quality alloy copper and iron alloy.

  •  In chemical industry, it is used to produce yellow phosphorus, calcium carbide, synthetic resin, etc.

  •  Used in the melting of cast steel and cast iron in the mechanical industry.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Products are mainly exported to East Asia, Central Asia, Southeast Asia, South America, North America and other markets and regions.

  • Implementation standard: IEC 60076 series.

Product advantagesl:

Leading technology:

  •  Large capacity, low loss, more energy saving, the actual measurement is better than GB and IEC standards.

  • High pressure copper tape winding technology, improve lightning resistance.

  •  Low voltage copper foil winding technology, high quality A class insulation material insulation, higher temperature resistance grade.

  •  Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  •  Iron core 45° full oblique joint step laminated structure.

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  •  Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Product parameters:

image.png

image.png


Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  •  Normal delivery period is 30 days.

  • Worldwide fast delivery.


What is an electric furnace transformer?

Furnace transformers are special - purpose transformers specifically used for electric arc furnaces, resistance furnaces, and other industrial electric furnaces. Its main function is to convert the high - voltage electrical energy provided by the power grid into low - voltage, high - current electrical energy suitable for the operation of electric furnaces. Furnace transformers are widely used in industries such as metallurgy, chemical engineering, and ceramics. The following are some key knowledge points of furnace transformers:

Definition and Characteristics:

  • Definition: A furnace transformer is a transformer specifically designed for electric furnaces, used to convert the high - voltage electrical energy of the power grid into low - voltage, high - current electrical energy suitable for the operation of electric furnaces.
    Characteristics:

  • High Current: Furnace transformers can provide high current to meet the high - power requirements of electric furnace heating.

  • Low Voltage: The output voltage is usually low to meet the working requirements of electric furnaces.

  • High Heat Resistance: Furnace transformers need to work in high - temperature environments, so they have good heat - resistant properties.

  • High Reliability: Furnace transformers need to operate continuously for a long time, so they have high reliability and a long service life.

  • High Efficiency: Furnace transformers usually have high efficiency to reduce energy loss and improve energy efficiency.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放