• 40.5kV HV Gas Insulated Switchgear GIS
40.5kV HV Gas Insulated Switchgear GIS
discuss personally
Model
ZF28-40.5 /2000-31.5
Basic info
Brand ROCKWILL
Model NO. 40.5kV GIS equipment switchgear (GIS)
Rated voltage 40.5kV
Rated normal current 2000A
Series ZF28
Product Detail

Description:

The 40.5kV GIS equipment represents a new - generation medium - voltage switchgear, evolved from high - voltage 126kV GIS technology. It finds applications in power systems, power generation, rail transit, petrochemicals, metallurgy, mining, building materials, and other large industrial sectors.

Tailored for the retrofit of old air - insulated switchgears, this product undergoes specialized optimization. With a cabinet width ranging from 1200mm to 1680mm and a depth from 2800mm to 3200mm, it enables retrofitting without the need to redo foundations, replace cables, or reinforce load - bearing structures.

Features:

  • Superior Insulation: Boasts a fully enclosed, gas - insulated structure. Eliminates issues like condensation, insulation deterioration - induced discharge, and contact overheating common in air - insulated switchgears.

  • Enhanced Safety & Control: Features a three - position disconnector with an electric mechanism and one - key sequential control. Prevents risks such as manual operation jamming of mobile circuit breakers and avoids tipping - related injuries.

  • Retrofit - Friendly: Ideal for retrofitting old air - insulated switchgears. No need to redo foundations, replace cables, or shut down the entire power station during the process.

  • Advanced Circuit Breaker: Equipped with a self - blasting SF6 circuit breaker. Switching reactive loads won’t cause current interception. Comes with a C2 - level certification report for back - to - back capacitor banks from Xi'an High Voltage Apparatus Research Institute Co., Ltd.

  • User - Adaptable Operation: Retains the operating habits of traditional switchgear products. Operation and maintenance personnel can quickly get accustomed to using this new product.

  • Eco - Friendly Option: Aligns with green environmental protection trends. Offers product solutions with mixed gases.

Technical Parameters:

企业微信截图_17284374895875.png

What is the internal structure of a GIS device?

The GIS conductive circuit is composed of several components. According to the working mode, it can generally be divided into: fixed contact (the electrical contact fastened with fasteners such as screws is called fixed contact, and the fixed contact has no relative movement in the working process. Such as the connection between the contact and the basin, etc.), contact contact (the electrical contact that can be separated in the working process is also called separable contact), sliding and rolling contact (in the working process, the contacts can slide or roll with each other, but the electrical contact that cannot be separated is called sliding and rolling contact. The intermediate contact of the switching appliance is the use of this electrical contact).


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放