• 15.6kV MV Auto Circuit outdoor vacuum recloser
  • 15.6kV MV Auto Circuit outdoor vacuum recloser
15.6kV MV Auto Circuit outdoor vacuum recloser
$5000.00
Model
RCW-S15.6M/1250-25C
RCW-S15.6M/1250-25
RCW-S15.6M/800-20C
RCW-S15.6M/800-20
RCW-S15.6M/630-16C
RCW-S15.6M/630-16
RCW-S15.6M/400-12.5C
RCW-S15.6M/400-12.5
Basic info
Brand ROCKWILL
Model NO. 15.6kV MV Auto Circuit outdoor vacuum recloser
Rated voltage 15.6kV
Rated normal current 400A
Rated short circuit breaking current 12.5kA
Power frequency withstand voltage 60kV/min
Rated lightning impulse voltage 125kV
manual closing Yes
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters:

image.png

image.png

Environmental requirement:

image.png

Product show:

正方型 单相.png

What are the technical parameters of the outdoor vacuum recloser?

  • Rated Voltage: 38kV, indicating the voltage level at which the recloser can operate normally. This ensures that the insulation and electrical performance of the device meet the required standards at this voltage.

  • Rated Current: Available in various specifications, such as 800A, 1200A, etc. This represents the maximum current that the recloser can carry continuously during normal operation. The appropriate rated current value should be selected based on the load current of the line.

  • Rated Short-Circuit Breaking Current: Reflects the breaking capability of the recloser during short-circuit faults. Common specifications include 16kA, 20kA, etc. A higher short-circuit breaking current indicates that the recloser can more reliably interrupt short-circuit currents, protecting the safety of the power system.

  • Rated Short-Circuit Making Current: Represents the maximum peak current that the recloser can close during a short-circuit fault. This value is typically greater than the rated short-circuit breaking current to ensure that the recloser can reliably close and withstand the impact of short-circuit currents at the moment of fault.

  • Reclosing Time Interval: Generally adjustable between 0.5 seconds and several seconds. Depending on the requirements of different power systems and types of faults, an appropriate reclosing time interval can be set to enhance the reliability and continuity of power supply.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
VS1 - Type Indoor High - Voltage Vacuum Circuit BreakerThe VS1 - type indoor high - voltage vacuum circuit breaker is an indoor device for three - phase AC 50Hz with a rated voltage of 12kV. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants, and substations. The circuit breaker arranges the main circuit and the operating mechanism on a special - shaped frame in a front - rear manner, that is, an integral layout. This structural
Echo
06/06/2025
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
ZN63A Indoor AC High-Voltage Vacuum Circuit BreakerThe ZN63A indoor AC high-voltage vacuum circuit breaker is a three-phase AC 50 Hz, 12 kV indoor device, used for starting, stopping, controlling, and protecting high-voltage motors of 10,000-ton free forging presses. AC high-voltage vacuum circuit breakers play a critical role in enterprise production. Timely and accurate resolution of their faults to quickly restore production is essential for enterprise development. During the start/stop of hi
Felix Spark
06/06/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
A vacuum circuit breaker is a type of circuit breaker in which both the arc - extinguishing medium and the insulating medium in the gap between the contacts after arc - extinction are vacuum. As a protection and control unit for power equipment and power - driven equipment in industrial and mining enterprises, indoor AC high - voltage vacuum circuit breakers have diverse applications and can be installed in fixed cabinets, middle - mounted cabinets, and double - layer cabinets. As a crucial elec
Felix Spark
06/06/2025
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
VS1 Indoor High - Voltage Vacuum Circuit Breaker Fault Analysis and Improvement MeasuresThe VS1 indoor high - voltage vacuum circuit breaker is an indoor switching device used in 12 kV power systems. Due to its excellent performance, it is especially suitable for places that require frequent operation at rated working current or multiple interruptions of short - circuit current. The operating mechanism of the VS1 indoor high - voltage vacuum circuit breaker is integrated with the circuit breaker
Felix Spark
06/05/2025
Generator Protection – Types of Faults & Protection Devices
Generator Protection – Types of Faults & Protection Devices
Common Generator Faults and Protection SystemsClassification of Generator FaultsGenerator faults are primarily categorized into internal and external types:Internal Faults: Arise from issues within generator components.External Faults: Stem from abnormal operating conditions or external network issues.Faults in prime movers (e.g., diesel engines, turbines) are mechanical in nature and defined during equipment design, though they must integrate with generator protections for tripping purposes.Typ
Edwiin
06/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放