• WDZK-Ⅳ Vacuum Switch Vacuum Tester
WDZK-Ⅳ Vacuum Switch Vacuum Tester
$3000.00
Model
VT-1700
Basic info
Brand Wone
Model NO. WDZK-Ⅳ Vacuum Switch Vacuum Tester
Rated frequency 50Hz
Series WDZK-Ⅳ
Product Detail

Description

WDZK-IV vacuum switch vacuum tester adopts a new type of excitation coil, and uses the magnetron discharge method to test the vacuum degree of the arc extinguishing chamber without disassembling the arc extinguishing chamber. At the same time, the microcomputer is used for synchronous control and data acquisition and processing, so that the field test sensitivity of the vacuum degree of the arc extinguishing chamber reaches 10-5Pa. The most prominent feature of this instrument is that it adopts a new type of excitation coil and data processing method, which realizes the measurement of vacuum degree without disassembly. This instrument has the advantages of convenient use, easy operation, no disassembly and high measurement accuracy. It is a practical detection instrument and is widely used in electric power, steel, petrochemical, textile, coal, railway and other departments that use vacuum switches.

Specifications

  •  Detection object: various types of vacuum switch tubes.

  •  Detection method: A new type of excitation coil is used to measure the vacuum tube without disassembly.

  • Scope of application: This instrument is a multi-purpose type, which can measure various types of vacuum switches.

  •  Detection range: 10-5—10-1 Pa.

  •  Measurement accuracy: 10-5—10-4 Pa, 10%

                                               10-4—10-3 Pa, 10%

                                               10-3—10-2 Pa, 10%

                                               10-2—10-1 Pa, 10%.

  •  Magnetic field voltage: 1700V.

  • Pulse electric field high voltage: 30KV.

  •  The distance of the switch tube when testing the vacuum degree: the distance of the normal use.

  •   Use environment: -20℃~40℃.

  •  Host weight: 24kg.

  •  Dimensions: 410×320×370(mm).

  •  Sampler: Magnetron coil.






Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放