• WD-G350 Integrated high frequency high voltage power supply
WD-G350 Integrated high frequency high voltage power supply
$4600.00
Model
HFHP-35
Basic info
Brand Wone
Model NO. WD-G350 Integrated high frequency high voltage power supply
Rated voltage AC220V+10%
Series WD-G350
Product Detail

Description

This product is mainly used for sampling impulse discharge of high-resistance fault waveform during fault testing of 35kV and below power cables and for impulse discharge when the fault point is accurately located. The sheath is used at precise points, and the burn-through capability can burn through the breakdown point in a short time and reduce the breakdown point resistance.

Feature

  • Integrated design, built-in capacitor, simple wiring.

  • Touch screen human-computer interaction, simple setting operation, intuitive and convenient display of instrument status.

  •  With voltage regulation, automatic voltage regulation and automatic protection functions.

  • The output high voltage has the function of single pulse and continuous pulse, respectively cooperate with the fault tester and the fixed point instrument to find the fault point.

  • The output high voltage has a DC output, which can be connected to an external ball gap for work, and the application is diversified.

  • Software controls vacuum shock spark discharge, self-adaptive discharge and pulse cycle.

  • With emergency stop button, automatic discharge function, automatic voltage reduction and discharge after emergency stop or shutdown, safe and reliable.

  • The continuous working time is not less than 6 hours, which meets the longest working time of the cable fault test.

  • Engineering chassis design, compact structure.

Specifications


Output mode pulse output/DC output
Output voltage  negative voltage, ≤35kV
Working current ≤40mA
Working mode ingle pulse/continuous pulse/DC output
Built-in capacitor 2.8uF/35kV
Discharge energy ≤1715J
Pulse period 3s~8s self-adaptive
Auto-discharge automatic discharge after shutdown
Working power supply power frequency 220V±10%
Display screen 800×480 resolution touch display
Working temperature  -10℃~40℃
Working humidity ≤80%
Altitude  ≤1000 meters
Dimensions 478(L)*370(W)*448(H) mm
Weight ≤28kg


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放