UT15BMAX
Basic info
Brand Wone
Model NO. UT15BMAX Digital multimeter
DC voltage 600.0mV/6.000V
AC voltage 600.0mV/6.000V
AC current 600.0µA/6000µA
DC current 600.0µA/6000µA
Series UT15BMAX
Product Detail

Description

UT15B MAX/UT17B MAX/UT18B MAX is a high-reliability True RMS digital multimeter with built-in VFD anti-interference start mode, 

which can filter the carrier frequency interference or various distortion voltage signals superimposed by the sine wave, 

and stably measure the output voltage and frequency of the inverter. 

Switching between entry frequency and duty cycle measurement under DC/AC function.

 The UT17B MAX/UT18B MAX is equipped with a 0.1°C partial temperature measurement function. 

The UT18B MAX has an LED measurement function that can measure up to 12V LEDs without distinguishing between positive and negative polarity. 

This series of products has full functions to achieve false detection protection of up to 30kVA energy, and the current gear is accidentally inserted into the input hole alarm, 

ensuring that users are safer and more assured in operation.

Industry applications

It is an indispensable measuring instrument for power electronics and other sectors. The main purpose is to measure voltage, current, and resistance. Generally, the multimeter can measure DC current, DC voltage, AC current, AC voltage, resistance and audio level, and some can also measure AC current, capacitance, inductance and some parameters of semiconductors.

Features

  • Large LCD 6000-bit analog-to-digital display, fast ADC/analog-to-digital converter.

  • Built-in VFD low-pass filtering, which can accurately measure distortion voltage and frequency conversion voltage.

  • The capacitance measurement is intelligent, and in the relative value measurement mode, the >6.2uF automatically exits the relative measurement mode.

  • VOLTAGE, CURRENT, AND RESISTANCE MEASUREMENTS CAPTURE MAXIMUM/MINIMUM (MAX/MIN) CHANGES (UT15B MAX/UT17B MAX).

  • Full-function false test protection, up to 1000V overvoltage impulse; And set the over-voltage and over-current alarm prompts.

  • The current gear is inserted into the input port by mistake to prompt an audible and visual alarm.

Technical parameters

UT15B MAX Technical Indicators
Basic Functions   Range Basic Accuracy
DC Voltage(V)  600.0mV/6.000V/60.00V/600.0V/1000V ±(0.4%+3)
AC Voltage(V) 600.0mV/6.000V/60.00V/600.0V/1000V ±(0.5%+5)
VFD(V) 600.0V ±(8%)
AC Current(A) 600.0µA/6000µA /60.00mA/600.0mA/6.000A/10.00A ±(1.2%+3)
DC Current(A) 600.0µA/6000µA /60.00mA/600.0mA/6.000A/10.00A ±(1.2%+3)
Resistance(Ω)  600.0Ω/6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ/60.00MΩ  ±(0.5%+2)
Capacitance(F) 6.000nF/60.00nF~600.0µF/6000µF ±(2.0%+5)
Frequency(Hz)  10Hz~10MHz ±(0.1%+3)
Duty Cycle(%) 10Hz~10MHz ±(1.0%+4)


 Special Features
Maximum display 6000
Diode testing
On-off test
Data is kept 
Maximum/minimum values
Relative value
Secondary backlight (adjustable)
Automatic shutdown 
Low battery prompt 
Sound and light alarm prompt 
LED Testing -
False jack alarm 
Wake up the √ with any key
Safety class CATIII  CATⅢ600V
Certifications CE, UKCA, ETL CE、UKCA、ETL、RoHS

Basic parameters
Power supply  2*1.5V AA
Body color  426U+1797C
The weight of the body 455g
The body size  182mm*91mm*45mm
Standard packing color box + cloth bag
Standard package quantity 10 units
Standard package size  480×370×195mm
The gross weight of the standard box  about 9kg

Product show

企业微信截图_17156635842995.png

企业微信截图_17156635547984.png

企业微信截图_17156636101196.png

企业微信截图_17156636606870.png


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放