• UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
discuss personally
Model
ZGS-500-33
ZGS-100-33
Basic info
Brand Vziman
Model NO. UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
Rated frequency 50/60Hz
Rated capacity 500kVA
Primary voltage 33kV
Series ZGS
Product Detail

Description:

This is a single-phase oil-immersed pad-mounted transformer certified by UL, specially designed for outdoor installation. It complies with UL 1561 (Dry-Type Transformer) or UL 1562 (Oil-Immersed Transformer) standards, suitable for capacity ranges of 15-500kVA, with voltage classes covering 7.2kV-34.5kV (high-voltage side) and 120-600V (low-voltage side). Its features include:

 

  • Structural Form: Adopts Pad-Mounted (box-type floor-mounted) design with a fully sealed structure, reaching IP65/66 protection rating, and can be directly placed on concrete foundations.
  • Insulation Medium: Uses mineral oil or high-flash-point silicone oil as insulation and cooling media, with fire and explosion protection performance (complying with UL 1203 explosion-proof standards).
  • Voltage Adaptation: The high-voltage side supports multiple voltage classes such as 7.2kV, 12.47kV, 13.8kV, 25kV, 34.5kV, etc., while the low-voltage side outputs 120V/240V (single-phase three-wire) or 208V/480V/600V (three-phase four-wire).

Core Functions:

  • Voltage Conversion: Steps down medium voltage (e.g., 7.2kV) to low voltage (e.g., 240V) to meet the power demand of residential, commercial, or small industrial loads.
  • Safety Isolation: Isolates the high and low voltage sides through an oil-immersed insulation design to improve safety.
  • Overload Protection: Equipped with a temperature controller and pressure relief valve, which automatically cuts off power when the oil temperature exceeds the set value (e.g., 80°C) or internal pressure is abnormal.
  • Environmental Adaptation: Withstands harsh environments such as high temperature, humidity, and dust, suitable for long-term outdoor operation.

Typical Application Scenarios:

  • Residential Power Distribution: Provides single-phase 240V power for individual villas and residential areas, supporting high-power devices such as air conditioners and water heaters.
  • Commercial Facilities: Supplies 120V/240V power for convenience stores, small shopping malls, gas stations, etc., meeting the needs of lighting and cash register systems.
  • Small Industrial Loads: Provides power for farms and small processing plants, such as driving water pumps and small motors.
  • Renewable Energy Access: Serves as a step-up or step-down device in photovoltaic and wind power projects, adapting to distributed power generation scenarios.

Parameter:

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!