• 12~40.5kV AC metal-enclosed gas-insulated switchgear
12~40.5kV AC metal-enclosed gas-insulated switchgear
discuss personally
Model
WS-G 12~40.5kV
Basic info
Brand Schneider
Model NO. WS-G 12~40.5kV AC metal-enclosed gas-insulated switchgear
Rated voltage 40.5kV
Series WS-G 12~40.5kV
Product Detail

Summary

WS-G Safe Reliable Environmentally friendly

Schneider Electric’s gas-insulated switchgear WS-G has very high safety and reliability, which can ensure the continuous and stable operation of the power system and the personal safety of operators. It also has a user-friendly operation interface, which is easy for on- site operators to operate. WS-G switchgear fully complies with the latest environmental requirements.

WS-G Simple Innovative Economical

WS-G is perfectly suitable for public and industrial power distribution networks, infrastructure engineering, mining, metallurgy, petrochemical, fuel gas, railway power supply, container bases and marine industries.

The WS-G uses a modern and innovative switchgear design concept and has a variety of options to choose from. It is a gas-insulated switchgear with rated voltage up to 40.5kV, rated current up to 3150A, and rated breaking current up to 40kA.

The WS-G is designed for single busbar or double busbar system. This compact, modular switchgear is extremely flexible and maintenance-free for its lifetime. It is also very suitable for places where space is limited or where old switches are retrofitted with existing foundations.

WS-G is an economical switch that can be spliced from the front of the switchgear when installed, extended, and removed. Thanks to the innovative busbar connection B-link, no gas handling operations are required on site.

WS-G has been tested in accordance with IEC standards, European EN standards and Chinese GB standards, as well as other national standards.

User Benefits

  • No gas handling required for expansions and cabinet replacement

  • Innovative, fault-resistant busbar connections

  • Friendly operation interface

  • Operational reliability and safety of personnel handing

  • Low lifetime costs

  • Environmentally friendly and easy to recycle

 

WS-G benefits and improvements

Innovative B-Link improves busbar connection
The busbar of each ws-g switchgear is installed in an independent inflatable chamber according to the system requirements. They are integrated into the insulating gas monitoring system and are not affected by the external environment. The connection with the adjacent switch cabinet bus is through our innovative bus connection system: B-link connection.

The B-link connection system does not require any maintenance.It is easy to install at the user’s site and does not require gas treatment.When expanding or replacing the switchgear, no gas handling is required and the gas chamber is not affected.The B-link connection system does not require any maintenance. It is easy to install at the user’s site and requires no gas handling. When expanding or replacing the switchgear, no gas handling is required and the gas chamber is not affected. The voltage control technology, housing grounding, soft and durable silicone rubber insulation used in the B-link connection system make the connection of the switchgear easier and the electric field distribution more uniform.


Further advantages of the B-Link system include:
All silicone rubber insulation parts have been installed on the switch cabinet in the factory, and partial discharge test has been conducted.

The on-site installation of B-link system is visible. When the B-link connection system of the adjacent switch cabinet is disassembled, an insulation distance is formed between the separated busbars without gas treatment. If necessary, the resistance of each section of busbar can be measured separately for the entire busbar system or one switchgear.

 

Reducing space requirements and improving space utilization

The WS-G saves investment costs due to its small space footprint.The WS-G can replace the old switchgear in the existing power distribution room.When the existing switchgear is dismantled, the WS-G can be debugged in sections. Reduce power outages.

The WS-G is designed for standard wall mounting. It does not require installation channels. All operations and maintenance procedures can be done in front of the cabinet.

Freestanding mounting options is also available.

Improved switchgear management - no gas handling required on site

The ws-g does not require gas treatment for installation or expansion in the field. All inflatable chambers delivered to the site for installation have a rated inflation pressure. All inflatable chambers have been tested for leakage prevention in the factory.

No gas treatment is required for the installation and renewal of the switch cabinet on site, and it does not affect the plenum.

 

Operating conditions and technical characteristics

Surrounding environment and working conditions
WS-G series switchgear is recommended to operate under normal working conditions in accordance with IEC62271, GB11022/T and GB 3906 standards.

Technical characteristics

 

WS-G main wiring scheme

Typical scheme
Single busbar system

 

Typical scheme
Dual busbar system

 

Typical scheme
Busbar auxiliary module

 

Cabinet arrangement (Single busbar segmentation)

 

WS-G application example

Spatial distribution map of civil engineering

 

 

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High voltage/Low voltage
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
9 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law