• RCW-T21.9M 21.9kV MV outdoor vacuum recloser
RCW-T21.9M 21.9kV MV outdoor vacuum recloser
$5000.00
RCW-T21.9M/1250-25C
RCW-T21.9M/1250-25
RCW-T21.9M/800-20C
RCW-T21.9M/800-20
RCW-T21.9M/630-16C
RCW-T21.9M/630-16
RCW-T21.9M/400-12.5C
RCW-T21.9M/400-12.5
Basic info
Brand ROCKWILL
Model NO. RCW T21.9M MV outdoor vacuum recloser
Rated voltage 21.9kV
Rated normal current 400A
Rated short circuit breaking current 12.5kA
Power frequency withstand voltage 85kV/min
Rated lightning impulse voltage 185kV
manual closing No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters:

Rated maximum voltage

21.9kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

12.5kA

Rated peak value withstand current

31.5kA

Rated 1min power frequencywithstand voltageSingle-phase Epoxy resin pole

85kV

Rated lightning impulse voltage(Single-phase Epoxy resin pole)

185kV

Operation sequence

C-0.5-CO-2-CO-5-CO(Magnetic actuator)

Mechanical life

n:30000(Magnetic actuator)

Power supply and operating voltage

110/220V( Customized)

Ratio of current transformer

400/1A( Customized)

Number of voltage sensorsSingle-phase Epoxy resin pole

≤2

Opening time

≤20ms(Magnetic actuator)

Closing time

≤30ms(Magnetic actuator)

Minimum creepage distance

31level4mm/kv

Minimum distance between phases

360mm

Potential transformer

110/220V( Customized)

Cable length

6,8,12m( Customized)

Cable clampSingle-phase Epoxy resin pole

4-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection& logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(*)

Over-voltage protection./Under voltage protection

Programable protection relay curves total 10 nos ANSI/IEC curves

Cold load pickup protection TCC +Hot line tag

Earth protection EF/SEF +Zone Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support(*)

Modbus communication protocol is optional(*)

IEC 60870-5-101 communication protocol support

IEC 60870-5-104 communication protocol support.(*)

The recloser can communicate through GPRS(Or GSM) modem with English or Specified language (*)

With optional functions for use

Rated currents, System phase current.

Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequency, 

power(kWh), reactive power(kV arh), power factor

With optional reclosing interval for user pre-program

Reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note: (*) mean should customized by manufacturer if needed

External dimensions:

企业微信截图_17105494892828.png

Environmental requirement:

Maximum temperature:

+40℃

Minimum temperature:

-30℃

Monthly average humidity

                          95%

Humidity:

                          90%

Above sea level:

2500m or higher

Ambient air not apparently polluted by corrosive and flammable gas, vapor

Product show:

正方型 单相.png

 What are the scenarios in which the 38kV outdoor vacuum recloser is used?

  • 38kV Overhead Transmission Lines: Widely used in branch lines and end lines of 38kV overhead transmission lines as control and protection devices. When a fault occurs in the line, the recloser can quickly interrupt the fault current and automatically perform reclosing operations, reducing downtime and improving power supply reliability.

  • 38kV Substation Outgoing Lines: Installed on the outgoing side of 38kV substations to control and protect the electrical connections between the substation and the transmission lines. When a fault occurs in the substation outgoing lines, the recloser can promptly isolate the fault, ensuring the safe operation of the substation, and quickly restore power supply through the reclosing function.

  • 38kV Distribution Network Automation System: As one of the key devices in the distribution network automation system, the recloser works in conjunction with other intelligent devices to achieve remote monitoring, control, and fault location functions for the distribution network. By communicating with feeder terminal units (FTUs) and distribution automation master stations, the recloser receives control commands and uploads operational status information, enhancing the automation level and operational management efficiency of the distribution network.