• JSZW12A-12R Indoor Three-phase Epoxy Resin voltage transformer
JSZW12A-12R Indoor Three-phase Epoxy Resin voltage transformer
discuss personally
Model
JSZW12A-12R-10/√3kV
Basic info
Brand Wone Store
Model NO. JSZW12A-12R Indoor Three-phase Epoxy Resin voltage transformer
Rated frequency 50/60Hz
Primary voltage 10/√3kV
Secondary voltage 110/√3V
Series JSZW
Product Detail

Product Overview

12kV Indoor Three-Phase Epoxy Resin Type
Epoxy resin casting and full enclosed construction, is used indoor for measuring voltage, electric energy and protective relaying in single-phase or three-phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV.The product has the feature of high reliability, low magnetism of core, large creepage distance of external insulation and maintenance free etc.The primary cone accords with IEEE 386-2007 figure 7.

Key Features

  • Epoxy Resin Casting and Enclosed Structure:The JSZW12A - 12R Indoor Three - phase Epoxy Resin voltage transformer features an epoxy resin casting and full - enclosed construction. This not only provides excellent electrical insulation but also protects the internal components from dust, moisture, and other contaminants. As a result, it is highly suitable for indoor use, ensuring stable operation in various indoor environments.
  • Accurate Three - phase Voltage Measurement:Designed to precisely measure three - phase voltages in single - phase or three - phase AC circuits with a frequency of 50Hz or 60Hz and a highest equipment voltage of 12 kV, it enables reliable voltage monitoring for power systems. The transformer's advanced design and high - quality materials contribute to minimizing measurement errors, ensuring that the measured voltage values accurately reflect the actual system voltages.
  • High Reliability and Low Core Magnetism:With a core that exhibits low magnetism, the transformer reduces energy losses during operation, enhancing its overall efficiency. Additionally, the high - reliability design ensures that it can continuously operate under normal working conditions for an extended period without significant performance degradation. This makes it a dependable choice for power system applications where continuous and accurate voltage transformation is crucial.
  • Large Creepage Distance of External Insulation:Featuring a large creepage distance of external insulation, the transformer can effectively withstand high - voltage stress and prevent electrical breakdowns caused by surface leakage currents. This is particularly important in environments where there may be humidity, pollution, or other factors that could affect the insulation performance. It helps maintain the integrity of the electrical insulation and ensures safe and stable operation of the transformer.

Echnical Data

  • Installation site: indoor
  • Rated frequency: 50/60Hz
  • Load power factor:  cosΦ=0.8 (lagging)
  • Technical standard accords with IEC 60044-2, (IEC 61869-1&3)

Specification

Note:

  • Rated output and limit output bleong to three-phase total output.
  • Upon request we are glad to offer transformers according to other technical specs.
Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
What are the causes of current transformer faults and the countermeasures for faults?
What are the causes of current transformer faults and the countermeasures for faults?
As a front - line maintenance technician, I deal with current transformers (CTs) daily. CTs convert high - magnitude primary current to low - magnitude secondary current for substation/line protection and measurement, operating in series long - term. However, they face faults from external (unbalanced loads, wrong wiring, etc.) and internal (insulation defects) issues. These faults, like secondary open - circuits or insulation breakdown, harm measurement accuracy, protection operation, and grid
Felix Spark
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!