• PRJ double winding Copper Strip Foil Winding Machine for machinery industry
  • PRJ double winding Copper Strip Foil Winding Machine for machinery industry
PRJ double winding Copper Strip Foil Winding Machine for machinery industry
$143400.00
Model
PRJ-1600D
PRJ-1600S
PRJ-1400S
PRJ-1400D
PRJ-1200D
PRJ-1200S
PRJ-1000D
PRJ-1000S
PRJ-600D
PRJ-600S
PRJ-800
PRJ-800S
Basic info
Brand Wone
Model NO. PRJ double winding Copper Strip Foil Winding Machine for machinery industry
Outer diameter(mm) 200~600mm
Width material(mm) 250~1600mm
Thickness of foil 0.5-3mm
Winding speed 24.5r/min
Working moment 15000N.M
Total power 63.58KW
Volume Number Double
Series PRJ
Product Detail

Description

The PRJ Foil Winding Machine is a foil coil winding system which is applicable for transformer and electrical industry. Foil coil is made of copper or aluminum foil of different thickness as conductor, with wide-band insulating material as layer insulation, and narrow-band insulating material as end insulation. The winding is completed by the foil winding machine and the coil is formed. Meanwhile, the welding of the inner and outer leads of the coil and binding of outer surface are completed. Double layer foil winding machine can be used to foil with narrow strips and winding into a wide foil coil or can support a thin foil strip with two  layers of thick foil coil. It can provide enough support to produce foil coil conforming to the requirements of the specification with the functions of the equipment. This machine is a necessary equipment for production of such electrical products.

 Composition

l● De-coiler of foil coil and foil offset regulating system

l● Foil edge burr remover and clean device

l● Foil feeding mechanism 

l● Foil offset regulating sensing system

l● Electrical tensioning device

l● Foil sheet shearing unit 

l● De-coiler for layer insulation 

l● Layer insulation edge cutting mechanism

l● Welding unit

l● Foil winding system 

l● End insulation strip wrapping system 

l● Discharge trolley 

l● Wound coil pressing device

l● Electrical control system

Specifications

1719538795338.jpg

1719538854188.jpg

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
×
Inquiry
Download