• GCS Type LV withdrawable switchgear
GCS Type LV withdrawable switchgear
discuss personally
Model
GCS-380
Basic info
Brand ROCKWILL
Model NO. GCS Type LV withdrawable switchgear
Rated frequency 50/60Hz
Rated insulation voltage 660(1000)V
Rated current Horizontal bus bar ≤4000A
Rated current Vertical bus bar 1000A
Rated voltage of main circuit AC 380(400)V
Rated voltage of auxiliary circuit AC 220V
Rated voltage of auxiliary circuit DC 110V
Series GCS
Product Detail

Description :

GCS LV withdrawable switchgear(hereinafter referred to as device) is developed according to the requirements from industry competent department, numerous electric users and design unit by original state mechanical department, united design group of power department. It conforms to national conditions and with higher technical performance index, and adapts the demands for power market development and able to compete with available imported products. The device passed the authentication jointly presided by two departments in July 1996 in Shanghai. It obtains the recognition and affirmation from manufacturing unit and power consumer construction. The device is applicable to the distribution system of power station, petroleum, chemical engineering, metallurgy, weaving and tall building industries etc. In the places with high automaticity and need computer to joint, such as large-scale power station and petrochemical industry system etc, it is the low voltage complete distribution device used in the generating and power supply system with three-phase AC50(60)Hz, rated working voltage 380V, rated current 4000A and below for distribution, motor central control and reactive power compensation. The device accords with standards IEC439- 1 and GB7251.1.

Main feature :

  • Main framework adopts 8MF bar steel. Both sides of bar steel is installed with 9.2mm mounting hole with modulus 20mm and 100mm. Inner installation is flexible and easy.

  • Two types of assembly form design for main framework, full assembly structure and partial (side frame and cross rail) welding structure for user selection. 

  • Each function compartment of device is separated mutually. The compartments are divided into function unit compartment, bus bar compartment and cable compartment. Each one has relative independent function. 

  • Horizontal bus bar adopts cabinet back level placed array pattern for enhancing the capacity of resisting electrodynamic force for bus bar. It is the basic measure for obtaining high short circuit strength capacity for main circuit. 

  • Cable compartment design makes cable outlet and inlet up and down convenient.

Main technical parameters:

GCS Type LV withdrawable switchgear.png

GCS Type LV withdrawable switchgear.png

Conditions for normal operating environment:

  • Ambient air temperature: -5℃ ~+40℃ and the average temperature should not exceed +35℃ in 24h.

  • Relative humidity should not exceed 50% at max temperature. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20℃ . But in view of the temperature change, it is possible that moderate dews will produce casually. 

  • Altitude above sea level should not exceed 2000M.     

  • Installation gradient not exceed 5° .

  • Indoor without dust, corrosive gas and rain water attack.

Interior structure Diagram:

GCS Type LV withdrawable switchgear.png

GCS Type LV withdrawable switchgear.png

Q:What is withdrawable switchgear?

A:Withdrawable switchgear is a type of electrical switchgear that allows the circuit breaker and other components to be easily withdrawn from the main body of the switchgear for maintenance, repair or replacement without having to disconnect the entire power supply system. It enhances the flexibility and maintainability of the power system.

Q:What is LV switchgear?

A:LV switchgear refers to low-voltage switchgear, which is mainly used in power distribution systems to control, protect and isolate electrical circuits at low voltages, typically below 1000V. It includes components like circuit breakers, switches, fuses and relays, and is crucial for the safe and reliable operation of low-voltage electrical systems in various applications such as buildings, factories and data centers.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Public.
GCS Type LV withdrawale switchgear
Manual English
Consulting
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放