• 24KV Indoor SF6 Load Break Switch
24KV Indoor SF6 Load Break Switch
discuss personally
Model
RLS-24B
Basic info
Brand ROCKWILL
Model NO. 24KV Indoor SF6 Load Break Switch
Rated voltage 24kV
Series RLS
Product Detail

Product Overview

The RLS-24B is an advanced indoor high-voltage SF6 load switch designed for 12kV/24kV power distribution systems. Utilizing SF6 gas as both an arc-extinguishing and insulation medium, it integrates three contactors (switching-on, switching-off, and grounding) in a compact, easy-to-install design. The RLS-24B and its variant, the RLS-12/24B (load switch + fuse combination), provide reliable protection and control for power supply equipment and substations, making them ideal for ring main units (RMUs), cable branch cabinets, and switching substations.

Compliant with GB3804-1990, IEC60256-1:1997, GB16926, and IEC60420, this switchgear ensures high performance in diverse electrical environments.

 

Key Features

  • SF6 Gas Technology– Superior arc-extinguishing and insulation properties

  • Compact & Lightweight– Space-saving design for easy installation

  • Triple Contactor System– Switching-on, switching-off, and grounding in one unit

  • High Adaptability– Suitable for harsh environments with minimal maintenance

  • Fuse Combination Option (RLS-12/24B)– Enhanced protection for transformers and cables

 

Product Advantages

  • Reliable Performance– SF6 ensures stable operation with minimal wear

  • Easy Operation– Simple mechanism reduces maintenance needs

  • Versatile Protection– Fuse-compatible model prevents overload damage

  • Wide Compliance– Meets GB, IEC, and international standards

  • Robust Construction– Resists humidity, altitude (up to 2500m), and mild corrosive conditions

 

Application Scenarios

  • Ring Main Units (RMUs)– Secure switching in urban power grids

  • Cable Branch Cabinets– Reliable power distribution for industrial zones

  • Switching Substations– Safe load control in medium-voltage networks

  • Transformer Protection– Fuse-integrated model prevents fault escalation

 

Environmental Specifications

  • Operating Temperature: -5°C to +40°C

  • Humidity Tolerance: Daily avg. 90% / Monthly avg. 95%

  • Max. Altitude: 2500m

Technical data

Matching dimension of SF6 load break switch-fuse combination Fig 1) SF6 load break switch without upper cubicle

Outline dimension & installation sizes

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Automatic backup switching (ABTS) devices are core components ensuring the safe, reliable, and stable operation of factory power grids. Their startup logic strictly follows the dual criteria of "loss of voltage in the working power supply + no - current detection", effectively avoiding misjudgments caused by secondary disconnection of voltage transformers (VTs) or maloperations of ABTS due to secondary circuit faults of current transformers (CTs). The activation condition requires both "no volta
James
07/03/2025
What tests need to be done on voltage transformers?
What tests need to be done on voltage transformers?
Practical Experience Sharing from an Electrical Engineer in the FieldBy Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early involvement in substation commissioning and equipment inspection, to now managing the maintenance and fault analysis of entire power systems, one of the most frequently encountered devices in my work has been the voltage transformer (VT / PT).Recently, a friend who's just starting out ask
Oliver Watts
07/03/2025
What are the development trends of voltage transformers?
What are the development trends of voltage transformers?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From early involvement in commissioning and maintenance of distribution rooms to later participation in electrical system design and equipment selection for large-scale projects, I’ve witnessed how voltage transformers have evolved — from traditional analog devices to intelligent, digital components.The other day, a new colleague from a power company asked
Echo
07/02/2025
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
With the rapid development of power systems, electronic voltage transformers (EVTs), as key measurement devices in power systems, their performance stability and reliability are crucial for the safe and stable operation of power systems. The electromagnetic compatibility (EMC) performance, as one of the core indicators of EVTs, is directly related to the ability of the device to work normally in complex electromagnetic environments and whether it will cause electromagnetic interference to other
Dyson
07/02/2025
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr
Felix Spark
07/02/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!