• 180kW DC/DC EV charger
  • 180kW DC/DC EV charger
180kW DC/DC EV charger
discuss personally
Model
WZ-180kW-1E
Basic info
Brand RW Energy
Model NO. 180kW DC/DC EV charger
Rated Output Rating 180KW
Output Voltage DC150-750V
Connector Options CCS2
Cable Length 5m
Input Voltage DC260-900V
Series DC EV Chargers
Product Detail

Parameters:

Name

DC/DC180kW-CCS1

Size(mm)

750mm X 600mm X 1290mm

Weight(KG)

250KGs

Screen Material

7’LCD

Shell Material

Sheet Metal

DC Input

Voltage

260VDC-900VDC

Current

≤200A

DC Output

Voltage

150VDC~750VDC

Voltage stabilization accuracy

<±0.5%

Current stabilization accuracy

≤±1%(Output load 20%~100% Rated range)

Voltage ripple factor

≤1%(150~750V, 0~20MHz)

Efficiency

≥ 95%, @750V, 50%~100% load current, rated 710V input

IP Degree of protection

IP54

Operating ambient temperature

-40℃~70℃, Above 50℃, use with derating

Relative humidity

≤95%RH, no condensation

Altitude

≤2000 meters,Derating for use above 2000 meters

Cooling mode

Forced air cooling

Remote monitoring mode

Ethernet / 4G/Wi-Fi

Startup mode

RFID/APP

Standby power

180W

Charging standard

IEC-62196-2;EN61851;ISO 15118

Installation method

Floor mounted

Metering accuracy

0.5

Safety protection function

Input Overvoltage Protection

≥900VDC

Input undervoltage protection

≤260VDC

Output overvoltage protection

DC150V ~ 750V can be set

Over temperature protection

Derating above 55 ℃; 75 ℃ protection shutdown

Short circuit protection

Yes

Emergency stop protection

Yes

Lightning protection

Level 2 lightning protection standard

How does a DC EV charging pile convert electricity?

The DC Fast Charger is a device specifically designed for rapidly charging electric vehicles. The DC charging pile initially obtains alternating current (AC) from the power grid, typically at a voltage of single-phase 230V or three-phase 400V, depending on the regional standards. Inside the charging pile, there are power electronic devices that are responsible for converting the AC from the grid into direct current (DC) suitable for use by the electric vehicle's battery.



Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!