• 800kV HV Gas Insulated Switchgear (GIS)
800kV HV Gas Insulated Switchgear (GIS)
discuss personally
Model
ZF27-800/6300
Basic info
Brand ROCKWILL
Model NO. 800KV GIS Gas Insulated Switchgear (GIS)
Rated voltage 800kV
Rated normal current 6300A
Series ZF27
Product Detail

Description:

ZF27-800 GIS, developed independently by company for controling, measuring, protecting and transforming the electric transmission line, consists of circuit breaker, current transformer, disconnector, earthing switch, main busbar, bushing and surge arrester, etc. The interrupter of circuit breaker is designed as double-break structure, and the hydraulic operating mechanism avoids the oil leak and slow-opening at zero pressure.

With rated current of 5000A and rated short-circuit breaking current of 50kA, this kind of GIS have been adopted in Substation GuanTing of 750kV power transmission project in Northwest China.

Main Features:

  •  All the hydraulic pipelines are set inside to avoid the leakage, which is domestic initiate.

  •  High current carrying performance with the rated current of 5000A.

  • Excellent insulating level has achieved the high standard of DL/T593-2006.

  • High mechanical endurance and reliability.

Technical Parameters:

1718680412874.png

What is the breaking and closing principle of gas-insulated switchgear?

Opening and Closing Principles:

  • The circuit breaker is the key component in GIS for interrupting and closing circuits. When the circuit breaker receives an opening command, the operating mechanism rapidly separates the moving contact from the stationary contact, creating an arc between them. At this point, the high temperature of the arc causes the SF₆ gas to decompose rapidly, producing a large number of positive and negative ions and free electrons. These charged particles interact with the charged particles in the arc, reducing the concentration of conductive particles in the arc, increasing the arc resistance, and absorbing the energy of the arc. This process causes the arc to cool and extinguish quickly, thereby interrupting the circuit current.

  • During the closing process, the operating mechanism moves the moving contact rapidly towards the stationary contact, ensuring reliable contact at the appropriate moment to complete the circuit connection. It is crucial to ensure that during the closing instant, no excessive inrush current or arc is generated.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放