• Central Power Conversion System(PCS, 1500V)
  • Central Power Conversion System(PCS, 1500V)
  • Central Power Conversion System(PCS, 1500V)
Central Power Conversion System(PCS, 1500V)
discuss personally
Model
WN-1250-HB-UD
Basic info
Brand Wone
Model NO. Central Power Conversion System(PCS, 1500V)
Max.Efficiency 99%
AC output power 1250kVA
Max. DC voltage 1500V
Max. DC current 1403A
Max. AC output current 1046A
Series Power Conversion System
Product Detail

Features

  • Max. efficiency up to 99%.

  • Full reactive power four-quadrant capability.

  •  IP65 protection degree .

  • Black start ability.

  • Support VSG function.

  • Millisecond-level Power response to EMS/SCADA.

  • Three level topology.

  • Use alone or in combination with MV station.

DC Parameters:

image.png

AC parameters (On-Grid):

image.png

AC parameters (Off-Grid):

image.png

General data:

image.png

What is the VSG function of an energy storage converter?

The Basic Principles of Virtual Synchronous Generator (VSG)

  • Simulating the Behavior of Synchronous Generator:VSG technology enables the energy storage converter to simulate the dynamic characteristics of traditional synchronous generators, including inertial response, damping characteristics, and frequency regulation ability, through control algorithms.

  • Inertial Response:Synchronous generators possess mechanical inertia. When the grid frequency changes, the kinetic energy of the generator rotor can temporarily absorb or release energy, thus stabilizing the frequency. VSG simulates this inertial response by controlling the output power of the energy storage converter, enhancing the frequency stability of the grid.

  • Damping Characteristics:Synchronous generators have damping characteristics that can suppress frequency oscillations. VSG simulates this characteristic by introducing a damping control algorithm, further improving the stability of the system.

  • Frequency Regulation:VSG can actively participate in the frequency regulation of the grid. By adjusting the output power of the energy storage converter, it helps the grid to return to the rated frequency.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
Selection of Primary Verification Circuit and Parameter Measurement for UHV GIS Current Transformers
In UHV GIS, current transformers are key to electric energy metering. Their accuracy determines power trade settlements, so on - site error verification perJJG1021 - 2007is needed. On - site, use power supplies, voltage regulators, and current boosters. Due to encapsulation in GIS, build test circuits via exposed grounding knives, bushings, and return conductors; right circuits simplify wiring and boost accuracy.Challenges like large test current, long circuits, and high impedance exist, but rea
Oliver Watts
07/07/2025
What are the polarity test methods for GIS current transformers?
What are the polarity test methods for GIS current transformers?
I’m Oliver, an 8 - year current transformer testing pro. Today, let’s break down new and old polarity test methods for GIS current transformers—how they work and their pros/cons.1.Testing Methods1.1New MethodPre - test ops: Open FDS21/FDS22 fast disconnectors + DS23 disconnector. Close CB21 breaker, then ES21/ES22 grounding disconnectors. Disconnect ES21’s SF6 - shell ground.Wiring: Connect battery between ES21’s moving contact (negative grounded) + ground electrode
Oliver Watts
07/07/2025
Exploring the Design and Application of Photoelectric Current Transformers in GIS
Exploring the Design and Application of Photoelectric Current Transformers in GIS
1.Design and Application Example of Photoelectric Current Transformer in GISThis article takes a 126kV GIS project as a specific example to deeply explore the design ideas and practical application of photoelectric current transformers in the GIS system. Since this GIS project was officially put into operation, the power system has remained stable, with no major failures occurring, and the operation status is relatively ideal.1.1 Design and Application Ideas of Photoelectric Current TransformerI
Dyson
07/07/2025
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
I'm Oliver, with 8 years of experience in current transformer testing. These are all practical experiences, shared with you1 Maintenance of Current TransformersHaving been in the business of current transformer testing for 8 years, I know a thing or two about their maintenance! The maintenance of current transformers is divided into minor repairs, intermediate repairs, and major overhauls.Minor repairs mainly involve opening the cover (if necessary) and changing the oil, usually carried out once
Oliver Watts
07/07/2025
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
Gas - insulated switchgear (GIS) , often called “SF6 combined electrical apparatus”, is widely used in power systems for its high reliability, small footprint, low noise, and low loss. It encloses high - voltage devices like circuit breakers, fast grounding switches, current transformers, and busbars in a grounded metal shell filled withSF6gas. Each device sits in a separate gas chamber with different pressures. The CT terminal block divides gas chambers, connects components, and eas