• 36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear
36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear
discuss personally
Model
KYN61-36/1250-25
KYN61-40.5/630-20
Basic info
Brand ROCKWILL
Model NO. 36KV 40.5KV air-insulated metal-clad withdrawable MV Switchgear
Rated voltage 36kV
Rated frequency 50/60Hz
Series KYN61-40.5
Product Detail

Description

KYN61-40.5( same as unigear Z3.2) air-insulated metal-clad withdrawable switchgear( hereinafter as "swit chgear") is a kind of MV switchgear.

It is designed as withdrawable module type panel, and the withdrawable part is fitted with VD4-36E, VD4-40.5 withdrawable vacuum circuit breaker manufactured by Cooper Nature company. It can also be fitted with isolation truck, PT truck, fuses truck and so on. It is applicable to three phase AC 50/60 Hz power system,

and mainly used for the transmission and distribution of electrical power and control, protection, monitoring of the circuit.

Standards and specifications

  • IEC60694 The commo n technical requirements of high voltage switchgear and controlgear.

  • IEC62271-200 A.C. metal enclosed switchgear and controlgear at the rated voltage of 1kV~52k V.

  • IEC62271-100 High voltage switchgear and controlgear-Part 100:Hi gh voltage A.C. circuit breaker.

  • GB3906 3.6~ 40.5kV alternating current metal enclosed switchgea r and controlgear.

  • GB1984 High voltage alternating current circuit breaker.

  • GB/T11022 The commo n technical requirements of high voltage switchgear and controlgear.

  • DL/T404 3.6~ 40.5kV alternating current metal enclosed switchgear and controlgear.

Service conditions:

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  •  Altitude no higher than 2500m.

  • The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

image.png

What are the structural characteristics of air-insulated metal armored withdrawable medium voltage switchgear?

Metal Clad:

  • The cabinet is made from high-quality cold-rolled steel plates, which are processed and bent using CNC equipment. It is assembled into a robust metal-clad structure using bolts, nuts, and other fasteners. This design provides high mechanical strength and protective capabilities, effectively preventing external objects from colliding with and damaging the internal electrical components.

Draw-Out Design:

  • Major electrical components, such as circuit breakers, contactors, and relays, are mounted on drawable trolleys. The trolleys and the cabinet are precisely aligned using guide rails and positioning devices, facilitating easy maintenance and repair. The trolleys can be withdrawn without interrupting power, allowing for the replacement or repair of faulty components. This significantly enhances the reliability and continuity of power supply.

Air Insulation:

  • Air is used as the insulating medium, with appropriate air gaps maintained between phases and between the phases and ground to meet insulation requirements. This design is simple and cost-effective, and it does not suffer from issues such as insulation aging or environmental pollution. However, the insulating properties of air are more susceptible to environmental factors. In harsh environments, such as high altitudes, humid conditions, or areas with heavy pollution, the insulation distance may need to be increased to ensure adequate performance.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放