• 33kV Three-phase Oil-immersed Power Distribution Transformer
33kV Three-phase Oil-immersed Power Distribution Transformer
discuss personally
Model
SF11-1000/33
Basic info
Brand Vziman
Model NO. 33KV Three-phase Oil-immersed Power Distribution Transformer
Rated capacity 1000kVA
Series Distribution Transformer
Product Detail

Product overview:

  • High reliability of operation verification in more than 50 countries and regions around the world.

  • Mainly used in 33kV distribution network, industrial and mining enterprises and civil building power supply and distribution system.

  • Roducts are mainly exported to Southeast Asia, the Middle East, Africa, South America and other countries and regions.

  • Standards: IEC 60076 series, IEC 6013, IEC 60214-1, IEC 60296; Gb1094-1996, GB/T6451-2008, GB/T7597-2007, etc.

Product advantages
Leading technology

  • High pressure copper tape winding technology, improve lightning resistance.

  • Low voltage copper foil winding technology, high quality A class insulation material insulation.

  • Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure.

The shell

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation .

winding

  •  Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  •  The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material

  •  Baowu Steel Group production of silicon steel sheet.

  •  High quality anaerobic copper from China.

  •  CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Other instructions

  •  The low-voltage outgoing terminal is tinned copper bar.

  •  The high-voltage outlet terminals are ring tinned bolts.

  •  Default no-load voltage regulator NLTC (OLTC can be customized) tap switch 5 or 7.

  • Transformers above 630KVA are protected by gas relays.

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc).

  • Other customization requirements (tap switch, color, oil pillow, etc).

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

  • Normal delivery period of 30 days, worldwide fast delivery.

What is high-voltage copper strip winding technology?


Definition:
High - voltage copper - tape winding technology refers to the use of copper tape as the winding material in the manufacturing of high - voltage transformers and reactors. The copper tape is wound layer by layer around the iron core or the bobbin through mechanical or automated equipment to form the required high - voltage winding. This technology can ensure the uniformity and compactness of the winding and improve the electrical performance and mechanical strength of the equipment.

Technical Features:

  • High Conductivity: Copper tape has excellent electrical conductivity, which can effectively reduce the resistance loss of the winding and improve the efficiency of the equipment.

  • Mechanical Strength: Copper tape has relatively high mechanical strength and can withstand the impact of high voltage and large current, improving the reliability and service life of the equipment.

  • Uniformity: Through precise winding processes, the uniform distribution of each layer of copper tape can be ensured, reducing the problems of local overheating and non - uniform electric field.

  • Compactness: Copper - tape winding can achieve a higher winding density, making the equipment more compact in volume and saving space.

  • Insulation Performance: During the copper - tape winding process, insulating materials can be added between each layer of copper tape to ensure good electrical insulation performance.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
What are the causes of current transformer faults and the countermeasures for faults?
What are the causes of current transformer faults and the countermeasures for faults?
As a front - line maintenance technician, I deal with current transformers (CTs) daily. CTs convert high - magnitude primary current to low - magnitude secondary current for substation/line protection and measurement, operating in series long - term. However, they face faults from external (unbalanced loads, wrong wiring, etc.) and internal (insulation defects) issues. These faults, like secondary open - circuits or insulation breakdown, harm measurement accuracy, protection operation, and grid
Felix Spark
07/03/2025
Testing of Optical Current Transformers (OCT)
Testing of Optical Current Transformers (OCT)
With the development of modern economy and science and technology, photoelectric current transformers (PECTs) have fully transitioned from the trial operation stage to practical application. As a front - line testing personnel, I deeply feel their importance in the power system during daily work. I also realize the necessity of conducting in - depth research on their testing systems and calibration methods. This not only promotes the engineering application of PECTs but also enables the accurate
Oliver Watts
07/03/2025
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Automatic backup switching (ABTS) devices are core components ensuring the safe, reliable, and stable operation of factory power grids. Their startup logic strictly follows the dual criteria of "loss of voltage in the working power supply + no - current detection", effectively avoiding misjudgments caused by secondary disconnection of voltage transformers (VTs) or maloperations of ABTS due to secondary circuit faults of current transformers (CTs). The activation condition requires both "no volta
James
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!