• 3.6kV-24kVThe Indoor metal-clad withdrawable switchgear
3.6kV-24kVThe Indoor metal-clad withdrawable switchgear
discuss personally
Model
KYN-12/2000-15
KYN-24/4000-40
KYN-7.2/1600-25
KYN-3.6/1250-25
Basic info
Brand ROCKWILL
Model NO. 3.6KV-24KVThe Indoor metal-clad withdrawable switchgea
Rated voltage 12kV
Series KYN
Product Detail

Description:

The Indoor metal-clad withdrawable switchgear(hereinafter short as switchgear) is a complete power distribution device for 3.6~40.5kV, 3-phase AC 50/60Hz,single-bus and single-bus sectionalized system.

It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc. so as to control, protect and monitor the system. The medium voltage switchgear meets IEC298,GB3906-91. In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc. It is truly a power distribution device with good performance.

In order to meet the requirements for wall mounting and front-end maintenance, the medium voltage switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

  • Enclosures able to withstand internal arcing.

  • 3 or 4 sides internal arc protection IAC: A-FL and A-FLR. Internal arc withstand: 12.5 kA 1s, 16 kA 1s and 20 kA 1s.

  • Mechanical and electrical interlocks, to prevent incorrect operations.

  • 100% factory-tested without the need for further tests on site.

  • Easy upgraded to meet your need and adapted to the extension of your installations.

  • Integration in factory-built outdoor substations for which the SM6 is particularly well designed.

  • Intelligent, connectable components like SC110 and TH110 provide continuous information about the health of your electrical installations, enabling asset management optimization through preventive maintenance.

Technical parameters:

image.png

Product detail:


企业微信截图_17211091605892.png

企业微信截图_17211092656460.png

企业微信截图_17211092834133.png

What is the working principle of the indoor metal armored pull-out  switchgear?

Circuit Control and Protection:

  • Circuit Control:

  • Circuit breakers control the opening and closing of circuits. The working principle of circuit breakers is based on electromagnetic induction and thermal effects. During normal operation, current flows through the contacts of the circuit breaker, which remain closed. When an overload condition occurs, and the current exceeds the rated current of the circuit breaker, the internal thermal trip mechanism will open the contacts due to the heat generated by the current, thereby interrupting the circuit.

  • In the event of a short circuit, the high short-circuit current will cause the internal electromagnetic trip mechanism to act instantly, quickly opening the contacts and protecting electrical equipment and lines from damage caused by excessive current.

Protection Devices:

  • Other protective devices, such as overcurrent relays and ground fault protection relays, are also equipped. These protection devices continuously monitor parameters such as current and voltage in the circuit. If any abnormality is detected, they send a trip signal to the circuit breaker, ensuring the safety of the circuit.

Power Distribution:

  • Power is introduced into the switchgear's busbar compartment via busbars. The busbars distribute the power to the circuit breakers in each branch. The circuit breakers then transmit the power to different load circuits, enabling the control of power supply to multiple loads. For example, in a building's power distribution system, medium-voltage power from a substation first enters the busbar of the switchgear and is then distributed to the distribution panels on each floor through circuit breakers, providing power to lighting, outlets, and other equipment on those floors.

Interlocking Functions:

  • To ensure operational safety, the switchgear is equipped with various interlocking mechanisms. For example:

  • The trolley can only be moved from the service position to the test or maintenance position when the circuit breaker is in the open (off) state.

  • There is an interlock between the grounding switch and the circuit breaker. When the grounding switch is in the closed (on) position, the circuit breaker cannot be closed, and vice versa.

  • These interlocking devices effectively prevent operator errors and avoid dangerous operations such as switching under load or closing the grounding switch while the circuit is energized.



Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放