• 22kV Oil-Immersed High-Voltage Side-Mounted Grounding Transformer
22kV Oil-Immersed High-Voltage Side-Mounted Grounding Transformer
discuss personally
Model
JDS-334-22
Basic info
Brand Rockwell
Model NO. 22kV Oil-Immersed High-Voltage Side-Mounted Grounding Transformer
Rated voltage 24kV
Rated frequency 50/60Hz
Cooling mode ONAN
Series JDS
Product Detail

Description

Earthing transformers are specially designed transformers. Their core function is to provide an artificial neutral point for power grids where the neutral point is either ungrounded or grounded through high impedance. This enables the neutral point to be grounded via an arc suppression coil or a small resistor.

The oil-immersed, high-voltage bushing side-mounted type grounding transformer (commonly referred to in the industry as the "high-voltage side-mounted grounding transformer") is a specialized variant. As the name implies, the high-voltage bushings (i.e., the terminals of the high-voltage winding) of this type of transformer adopt a side-mounted design, positioned on the side of the transformer tank rather than on the top.

This structural design significantly reduces the overall installation height of the equipment, making it particularly suitable for space-constrained installations, such as indoor GIS (Gas-Insulated Switchgear) rooms, compact substations, and retrofit projects in existing substations.

Features

  • Space Optimization: The side-exit bushings significantly reduce the overall equipment height, enabling easy adaptation to low-clearance spaces or retrofit requirements in existing substations, saving civil engineering costs.

  • Flexible Grounding: Provides a stable neutral point, allowing flexible connection to a resistor cabinet / arc suppression coil. This effectively limits ground fault current, suppresses overvoltages, and enhances system safety and power supply continuity.

  • High Reliability:
    Impact Resistance: Designed to withstand the impact of unbalanced currents and zero-sequence currents generated by system single-phase-to-ground faults.
    Low Losses: Employs high-quality silicon steel cores and advanced manufacturing processes to ensure low no-load and load losses.
    Robust Insulation: Features a reliable high-voltage insulation structure with low partial discharge levels.
    Excellent Protection: High enclosure protection rating (IP), providing effective dust and moisture resistance.

  • Simplified Installation & Maintenance: Compact structure combined with the side-exit wiring design optimizes both on-site installation and subsequent maintenance operations.

Main Technical Parameters

 

Know your supplier
Rockwell
Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.
Main Categories
High voltage/Low voltage/Electrical fittings
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
60000m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!