• 2.4–10.24 KWh Wall - Mounted Energy Storage Battery
2.4–10.24 KWh Wall - Mounted Energy Storage Battery
$9828.00
Model
W48200
W48200
W48200
W48200
W48100
W48100
W48100
W48100
W4850
W4850
W4850
W4850
Basic info
Brand RW Energy
Model NO. Wall mounting energy storage battery
Energy storage capacity 10.24kWh
Cell quality Class A
Series Residential energy storage
Product Detail

企业微信截图_17292161181040.png                                           

Peculiarity

  • High energy density.

  • Equipped with BMS battery management system, longer cycle life.

  • Beautiful appearance; Free combination, convenient installation.

  • The panel integrates a variety of interfaces, supports multiple protocols, and ADAPTS to most photovoltaic inverters and energy storage converters.

  • Can be customized adjustment management battery charging and discharging strategy.

  •  Modular design, easy maintenance.

Technical parameter

image.png

image.png

Note:

  • The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.

  •  Class A cell warranty 60 months, Class B cell warranty 30 months.

 How wall-mounted energy storage batteries work?

  • Energy storage:When the power supply is sufficient, the wall-mounted energy storage battery converts alternating current (AC) from the power grid into direct current (DC) through a charger or inverter and stores it in the internal battery.
    Batteries usually adopt lithium-ion battery technologies such as lithium iron phosphate (LiFePO4), ternary material (NMC), etc. These batteries have the characteristics of high energy density and long lifespan.

  • Energy management:The Battery Management System (BMS) monitors the state of the battery, including parameters such as voltage, current, and temperature, and optimizes the battery's charging and discharging process through algorithms to ensure the safe and efficient operation of the battery.
    The BMS includes various protection mechanisms such as overcharge/overdischarge protection, over-temperature protection, and short-circuit protection.

  • Energy conversion:The inverter converts the direct current (DC) stored in the battery into alternating current (AC) for use by household appliances.
    The inverter is also responsible for ensuring the quality of the output electrical energy, such as voltage stability and accurate frequency.

  • Energy release:When power demand increases or supply is insufficient, the wall-mounted energy storage battery converts the stored direct current into alternating current through the inverter and outputs it to terminal devices for use through sockets or other interfaces.
    Through intelligent algorithms, the Energy Management System (EMS) can dynamically adjust the charging and discharging strategies according to electricity prices and grid demands to maximize economic benefits.


Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr
Felix Spark
07/02/2025
In which directions will dry-type transformers develop in the future?
In which directions will dry-type transformers develop in the future?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From my early days doing commissioning and maintenance in distribution rooms, to later participating in electrical system design and equipment selection for large-scale projects, I’ve witnessed how dry-type transformers have evolved from traditional tools into smarter, greener devices.Recently, a new colleague asked me:“What’s the current state of dry
Echo
07/02/2025
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m