• 180kW DC EV charger
  • 180kW DC EV charger
180kW DC EV charger
discuss personally
Model
WZ-180kW-1E
Basic info
Brand RW Energy
Model NO. 180kW DC/DC EV charger
Rated Output Rating 180kW
Output Voltage DC150-750V
Connector Options CCS2
Cable Length 5m
Input Voltage DC260-900V
Series DC EV Chargers
Product Detail

Description:
Designed for high-efficiency EV charging, this 180kW DC fast charger employs advanced DC/DC conversion technology and supports mainstream standards like CCS, CHAdeMO, and GBT,  Integrated with intelligent temperature control and power management systems, it maintains stable output in extreme environments from -30°C to 55°C, making it ideal for high-frequency charging scenarios such as commercial parking lots, highway rest areas, and logistics parks.

Key Features:

Ultra-Fast Charging Performance

  • Charges vehicles from 10% to 80% in just 30 minutes at 180kW, suitable for passenger cars and light commercial vehicles.

  • Liquid-cooled thermal management ensures temperature differentials within ±3°C, enabling continuous high-power operation.

Universal Compatibility

  • Seamlessly switches between CCS1/CCS2, CHAdeMO, and GBT protocols, eliminating the need for adapters.

  • Directly compatible with Tesla, BYD, NIO, Volkswagen, and 95%+ global EV models.

Intelligent Management System

  • Built-in BMS communication interface optimizes charging curves based on real-time battery status, extending battery life.

  • Supports OTA updates and integrates with third-party platforms for data analytics, remote monitoring, and predictive maintenance.

Comprehensive Safety

  • Equipped with overvoltage/overcurrent protection, leakage detection, lightning protection, and IP54-rated enclosure for outdoor durability.

  • Ergonomic charging gun with PEL (Protection against Electric Shock) and mechanical locking mechanism.

Flexible Deployment

  • Floor-standing or wall-mounted installation options with a compact 0.5㎡ footprint.

  • Grid-friendly design compliant with IEC 61000-3-2, minimizing harmonic interference.

Parameters:

Name

DC/DC180kW-CCS1

Size(mm)

750mm X 600mm X 1290mm

Weight(KG)

250KGs

Screen Material

7’LCD

Shell Material

Sheet Metal

DC Input

Voltage

260VDC-900VDC

Current

≤200A

DC Output

Voltage

150VDC~750VDC

Voltage stabilization accuracy

<±0.5%

Current stabilization accuracy

≤±1%(Output load 20%~100% Rated range)

Voltage ripple factor

≤1%(150~750V, 0~20MHz)

Efficiency

≥ 95%, @750V, 50%~100% load current, rated 710V input

IP Degree of protection

IP54

Operating ambient temperature

-40℃~70℃, Above 50℃, use with derating

Relative humidity

≤95%RH, no condensation

Altitude

≤2000 meters,Derating for use above 2000 meters

Cooling mode

Forced air cooling

Remote monitoring mode

Ethernet / 4G/Wi-Fi

Startup mode

RFID/APP

Standby power

180W

Charging standard

IEC-62196-2;EN61851;ISO 15118

Installation method

Floor mounted

Metering accuracy

0.5

Safety protection function

Input Overvoltage Protection

≥900VDC

Input undervoltage protection

≤260VDC

Output overvoltage protection

DC150V ~ 750V can be set

Over temperature protection

Derating above 55 ℃; 75 ℃ protection shutdown

Short circuit protection

Yes

Emergency stop protection

Yes

Lightning protection

Level 2 lightning protection standard

How does a DC EV charging pile convert electricity?

The DC Fast Charger is a device specifically designed for rapidly charging electric vehicles. The DC charging pile initially obtains alternating current (AC) from the power grid, typically at a voltage of single-phase 230V or three-phase 400V, depending on the regional standards. Inside the charging pile, there are power electronic devices that are responsible for converting the AC from the grid into direct current (DC) suitable for use by the electric vehicle's battery.



Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!