• 15kV MV outdoor vacuum Auto Circuit recloser
  • 15kV MV outdoor vacuum Auto Circuit recloser
15kV MV outdoor vacuum Auto Circuit recloser
$7500.00
Model
RCW-F15G/630-16
RCW-F15G/400-12.5C
RCW-F15G/1250-25C
RCW-F15G/1250-25
RCW-F15G/800-20C
RCW-F15G/800-20
RCW-F15G/400-12.5
Basic info
Brand ROCKWILL
Model NO. 15kV MV outdoor vacuum Auto Circuit recloser
Rated voltage 15kV
Rated normal current 630A
Rated short circuit breaking current 16kV
Power frequency withstand voltage 45kV/min
Rated lightning impulse voltage 120kV
manual closing No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range

  • With optional relay protection and logic for user selection

  • With optional communication protocols and I/O ports for users to choose

  • PC software for controller testing, setup, programming, updates

Parameters:

Rated maximum voltage

15KV

Rated maximum current

400A

Rated frequency

50Hz

Rated short circuit breaking current

12.5KA

Rated peak value withstand current

31.5KA

Rated 1min power frequencywithstand voltageThree-phase Epoxy resin pole

45KV

Rated lightning impulse voltage(Three-phase Epoxy resin pole)

120KV

Operation sequence

C-0.5-CO-2-CO-5-CO(Magnetic actuator)

Mechanical life

n:30000(Magnetic actuator)

Power supply and operating voltage

110/220V( Customized)

Ratio of current transformer

400/1A( Customized)

Number of voltage sensorsThree-phase Epoxy resin pole

≤6

Opening time

≤30ms(Magnetic actuator)

Closing time

≤40ms(Magnetic actuator)

Minimum creepage distance

31level4mm/kv

Minimum distance between phases

360mm

Potential transformer

110/220V( Customized)

Cable length

6,8,12m( Customized)

Cable clampThree-phase Epoxy resin pole

4-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection& logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(*)

Over-voltage protection./Under voltage protection

Programable protection relay curves total 10 nos ANSI/IEC curves

Cold load pickup protection TCC +Hot line tag

Earth protection EF/SEF +Zone Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support(*)

Modbus communication protocol is optional(*)

IEC 60870-5-101 communication protocol support

IEC 60870-5-104 communication protocol support.(*)

The recloser can communicate through GPRS(Or GSM) modem with English or Specified language (*)

With optional functions for use

Rated currents, System phase current.

Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequency, 

power(kWh), reactive power(kV arh), power factor

With optional reclosing interval for user pre-program

Reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note: (*) mean should customized by manufacturer if needed

Environmental requirement:

Maximum temperature:

+40℃

Minimum temperature:

-30℃

Monthly average humidity

                          95%

Humidity:

                          90%

Above sea level:

2500m or higher

Ambient air not apparently polluted by corrosive and flammable gas, vapor

Product show:

企业微信截图_17104644186528.png


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
A vacuum circuit breaker is a type of circuit breaker in which both the arc - extinguishing medium and the insulating medium in the gap between the contacts after arc - extinction are vacuum. As a protection and control unit for power equipment and power - driven equipment in industrial and mining enterprises, indoor AC high - voltage vacuum circuit breakers have diverse applications and can be installed in fixed cabinets, middle - mounted cabinets, and double - layer cabinets. As a crucial elec
Felix Spark
06/06/2025
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
VS1 Indoor High - Voltage Vacuum Circuit Breaker Fault Analysis and Improvement MeasuresThe VS1 indoor high - voltage vacuum circuit breaker is an indoor switching device used in 12 kV power systems. Due to its excellent performance, it is especially suitable for places that require frequent operation at rated working current or multiple interruptions of short - circuit current. The operating mechanism of the VS1 indoor high - voltage vacuum circuit breaker is integrated with the circuit breaker
Felix Spark
06/05/2025
Generator Protection – Types of Faults & Protection Devices
Generator Protection – Types of Faults & Protection Devices
Common Generator Faults and Protection SystemsClassification of Generator FaultsGenerator faults are primarily categorized into internal and external types:Internal Faults: Arise from issues within generator components.External Faults: Stem from abnormal operating conditions or external network issues.Faults in prime movers (e.g., diesel engines, turbines) are mechanical in nature and defined during equipment design, though they must integrate with generator protections for tripping purposes.Typ
Edwiin
06/05/2025
Classification of Electric Power Distribution Network Systems
Classification of Electric Power Distribution Network Systems
The typical electric power system network is categorized into three main components: generation, transmission, and distribution. Electric power is produced in power plants, which are often located far from load centers. As a result, transmission lines are employed to deliver power over long distances.To minimize transmission losses, high-voltage power is used in transmission lines, and the voltage is reduced at the load center. The distribution system then delivers this power to end-users.Types
Edwiin
06/05/2025
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
It is well-known that single-phase and three-phase systems are the most prevalent configurations for power transmission, distribution, and end-use applications. While both serve as fundamental power supply frameworks, three-phase systems offer distinct advantages over their single-phase counterparts.Notably, multi-phase systems (such as 6-phase, 12-phase, etc.) find specific applications in power electronics—particularly in rectifier circuits and variable frequency drives (VFDs)—wher
Edwiin
06/05/2025
How Many Poles and Towers are Situated Within a 1-km Span?
How Many Poles and Towers are Situated Within a 1-km Span?
The number of distribution poles and transmission towers within a 1-kilometer stretch of overhead lines varies significantly based on multiple factors, including voltage level, power line type, supporting structure, geographical location, local regulations, and specific grid requirements.In urban areas, distribution utility poles are typically positioned at closer intervals, while in rural regions, they are spaced farther apart. Additionally, the use of taller structures for higher-voltage trans
Edwiin
06/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放