• 126kV 145kV high voltage SF6 circuit breaker
126kV 145kV high voltage SF6 circuit breaker
discuss personally
Model
LW36-145(W)/T4000-40
LW36-145(W)/T3150-40
LW36-126(W)/T4000-40
LW36-126(W)/T3150-40
Basic info
Brand ROCKWILL
Model NO. 126kV 145kV high voltage SF6 circuit breaker
Rated voltage 145kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series LW36-126(145)
Product Detail

Product introduction:

LW36-126(145) (W) circuit breaker is suitable for single-phase operation, three-phase electrical linkage and three-phase mechanical linkage, Grid frequency 50 / 60Hz, neutral grounded system and neutral ungrounded system, C2 level of back-to-hack capacitor bank and C2 level of no-load line-Charing breaking capacity and no-load cable-charging breaking capacity.  products have reached the leading domestic and international advanced level in advanced technology and quality reliability.

By adopting SF6 gas as the arc extinguisher and insulation medium, using advanced self-energy power arc extinguishing technology and being equipped with new type spring actuating mechanism, this product has features such as long electrical end-durance, less operating power, low noise, and high reliability. it has a simple structure, small size, long maintenance-free cycle. In the current trend of oil-free and high-capacity electricity equipment’s.

Main characteristic:

  • Reliable breaking performance: This circuit breaker can consecutively break 40kA short circuit current for 22 times without overhaul; Neutral grounded system and neutral ungrounded system, first-pole-to-clear factor 1.3/1.5; C2 level of no-load line-charging breaking capacity and no-load cable-charging breaking capacity, C2 level of the back-to-back capacitor bank breaking capacity, no restrike.

  • Reliable mechanical operating performance: The mechanical life of the circuit breaker under continuous operation can reach up to 10000 times M2 class.

  •  Reliable seismic performance: Comply with lEEE693-2018 1.0g high seismic level and ETG Chile seismic standard requirements.

  • Reliable current-carrying function: After 3780A temperature-rise test, the temperature-rise values at all points still have much margin.22.

  •  Reliable insulation ability: creepage distance of external insulation>31mm/kV; strong pollution resistance; suitable for safe running in hard environments with an altitude of no more than 3000m.

  • Reliable sealing performance. it is guaranteed that the SF6 gas has an annual gas leakage rate of far less than 0.5%.

  • Strict dehumidification process for component parts of the product the SF6 water content is far lower than similar products.

  • Simple structure, long overhaul cycle, convenient on-site installation and debug, safe and reliable running experience of more than 25000 sets, applied worldwide.

  • Optional phase closing device.

  • Self-energy arc extinguishing principle is adopted for the circuit breaker, The operating power is low.The valve plate of the arc extinguishing compartment is made of new-type lightweight Zinc-base alloy. Compared with the traditional materials adopted for similar products, this material has more stable and reliable gas feature and breaking performance;

  • The spout is made of import PTFE mixed with other micro-components. lt has stable breaking performance and strong ablation resistance.

  • The unique locking-up measure is used for the insulating pulling rod of the breaker to ensure more reliable running of the breaker.

  • Spring actuating mechanism with small operating power, light weight, and low noise is adopted for zero leakage and high reliability, High-strength cast aluminum machine fame is adopted for high strength, zero welding stress, and pleasing exterior appearance. The important component pats in the mechanism are forged with quality alloy steel for high strength and abrasion resistance, which can ensure low fault rate under frequent operation of the breaker.

  • The product has a novel and lively exterior appearance and compact structure, The installation foundation frame is made of thick steel board being overall bended. Hot zinc impregnation is adopted for the surface, The exposed fastening pieces are high-strength hot-galvanized bolts, The interval driving connecting rods are made of high-strength aluminum sectional material or stainless stool sectional malarial, The case of the mechanism is made of stainless steel ,The product has excellent ant-corrosion performance.

Main technical parameters:

1732518156932.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

What are the performance characteristics of the canister circuit breaker?

High Insulation Performance:

  • High Insulation Performance: Whether using sulfur hexafluoride (SF6) gas or insulating oil as the insulating medium, tank-type circuit breakers possess a high level of insulation. They can withstand system operating voltages and various overvoltages, ensuring the safety of both equipment and personnel.

Strong Arc-Quenching Capability:

  • Strong Arc-Quenching Capability: The special design of the arc quenching chamber and the arc-quenching medium enable tank-type circuit breakers to rapidly extinguish arcs when interrupting short-circuit currents. This reduces the burn damage to the contacts, extends the electrical life and interrupting performance of the circuit breaker, and lowers the downtime and maintenance costs associated with faults.

Good Environmental Adaptability:

  • Good Environmental Adaptability: The enclosed tank structure provides excellent resistance to contamination, moisture, and windblown sand. This allows the circuit breaker to operate stably in various geographical environments and climatic conditions, making it suitable for outdoor substations, industrial and mining enterprises, and other locations.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!