Brand | ROCKWILL |
Model NO. | 12kV indoor high-voltage load break switch |
Rated voltage | 12kV |
Rated normal current | 400A |
Rated frequency | 50/60Hz |
Series | FN |
Product Overview
The FN5 - 12 indoor AC high - voltage load break switch (hereinafter referred to as the load break switch) is suitable for AC 50Hz, 12kV networks. It is used for breaking load current and closing short - circuit current. The load break switch with a fuse can cut off short - circuit current and be used as a protection switch.
This load break switch can be equipped with the CS6 - 1 manual operating mechanism and the special CS manual operating mechanism for this product.
Key Features
Precise Current Control:Suitable for 12kV, 50Hz AC systems. It can stably break load current and close short - circuit current, ensuring normal operation and maintenance of the power grid as well as emergency operations during faults.
Extended Protection Function:When paired with a fuse, it can cut off short - circuit current and act as a protection switch, providing overload and short - circuit dual protection for power equipment and simplifying the protection levels of the distribution network.
Wide Scene Adaptability:Focused on indoor 12kV AC networks. It is suitable for typical indoor power distribution scenarios such as ring main units and box - type substations, meeting the needs of distribution network construction.
Flexible Mechanism Configuration:Supports the CS6 - 1 general manual operating mechanism and can also be adapted to the special CS mechanism, compatible with different operating habits and equipment matching requirements.
Mature Technical Architecture:Iterated based on the classic FN5 - 12 model. It has a compact structure, stable arc - extinguishing performance, high long - term operation reliability, and reduces operation and maintenance costs.
Technical Parameters
Name |
Unit |
Value |
Rated Voltage |
kV |
12 |
Maximum Operating Voltage |
kV |
12 |
Rated Frequency |
Hz |
50 |
Name |
Unit |
Value |
|
Rated Current |
A |
400 |
630 |
Rated Short - time Withstand Current (Thermal Stable Current) |
kA/S |
12.5/4 |
20/2 |
Rated Peak Withstand Current (Dynamic Stable Current) |
kA |
31.5 |
50 |
Rated Closed - loop Breaking Current |
A |
400 |
630 |
Rated Active Load Breaking Current |
A |
400 |
630 |
5% Rated Active Load Breaking Current |
A |
20 |
31.5 |
Rated Cable Charging Breaking Current |
A |
10 |
|
Rated No - load Transformer Breaking Current |
No - load Current of 1250kVA Transformer |
||
Rated Short - circuit Making Current |
kA |
31.5 |
50 |
Load Current Breaking Times |
Load/Time |
100%/20 |
30%/75 |
1min Power Frequency Withstand Voltage (Effective Value, to Ground, Phase - to - Phase/Isolation Break) |
kV |
42/48 |
|
Power Frequency Withstand Voltage, Between Isolation Breaks |
kV |
53 |
|
Lightning Impulse Withstand Voltage (Peak Value, to Ground, Phase - to - Phase/Isolation Break) |
kV |
75/85 |
|
Opening and Closing Operating Torque (Force) |
N·m (N) |
90(80) |
100(200) |
Technical Parameters of Fuse
Model |
Rated Voltage (kV) |
Rated Current of Fuse (A) |
Rated Breaking Current (kA) |
Rated Current of Fuse Element (A) |
RN3
|
12
|
50 |
12.5 |
2, 3, 5, 7.5, 12, 15, 20, 30, 40, 50 |
75 |
12.5 |
75 |
||
100 |
12.5 |
100 |
||
200 |
12.5 |
150, 200 |
||
SDL*J |
12 |
40 |
50 |
6.3, 10, 16, 20, 25, 31.5, 40 |
SFL*J |
12 |
100 |
50 |
50, 63, 71, 80, 100 |
SKL*J |
12 |
126 |
50 |
125 |
Altitude: Not exceeding 1000m;
Ambient Air Temperature: Upper limit +40°C, Lower limit -25°C (Not lower than -5°C for motor - operated mechanisms);
Relative Humidity: Daily average not greater than 95%, Monthly average not greater than 90% (+25°C);
Ambient air should be free from obvious pollution by corrosive or flammable gases, water vapor, etc.;
No frequent severe vibration.